Performance of an ancillary test for cervical cancer that measures miRNAs and cytokines in serum and cervical mucus

Author:

Fujii Takuma123ORCID,Nishio Eiji2,Tsukamoto Tetsuya4ORCID,Kukimoto Iwao5,Iwata Aya12

Affiliation:

1. Department of Gynecology, School of Medicine Fujita Health University Toyoake Aichi Japan

2. Department of Obstetrics and Gynecology, School of Medicine Fujita Health University Toyoake Aichi Japan

3. Fujita Health University Okazaki Medical Center Okazaki Aichi Japan

4. Department of Pathology, School of Medicine Fujita Health University Toyoake Aichi Japan

5. Pathogen Genomics Center National Institute of Infectious Diseases Tokyo Japan

Abstract

AbstractCurrently, human papillomavirus tests and cytology are used to screen for cervical cancer. However, more accurate ancillary screening tests are needed. MicroRNAs (miRNAs) and cytokines are promising biomarkers that are aberrantly expressed in cervical cancer. Therefore, the potential of developing new screening markers based on the levels of miRNAs and cytokines in serum and local mucus samples from the same patients with cervical neoplasia was investigated. miRNA screening was performed by microarray and measurement using real‐time reverse‐transcriptase PCR. Cytokine were measured using multiplex bead assay, and changes in expressions were analyzed based on disease severity. As lesions progressed, miR‐20b‐5p, −155‐5p, −144‐3p, −451a, and −126‐3p expression levels were increased in mucus, and miR‐16‐5p, −223‐3p, and ‐451a expression levels were decreased in serum. Regarding cytokines, IL‐6, IL‐8, monocyte chemoattractant protein‐1, Eotaxin, interferon‐γ, and RANTES were increased, whereas granulocyte–colony‐stimulating factor (G‐CSF) was significantly decreased in mucus. miRNAs and cytokines in serum did not have high diagnostic accuracy. However, a combination of miR‐20b‐5p, ‐451a, ‐126‐3p, Eotaxin, as well as G‐CSF in mucus samples, had high diagnostic accuracy with an area under the receiver operating characteristic curve of 0.989 (0.979–0.999). Our results suggest that using mucus for this ancillary test is more beneficial than serum.

Funder

Japan Society for the Promotion of Science

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3