Bleb morphology of glaucoma drainage devices on magnetic resonance imaging

Author:

Correia Barão Rafael12ORCID,Berhanu David34ORCID,Bernardo Matos Diogo12ORCID,Barata André Diogo12ORCID,Sousa Rita3ORCID,Abegão Pinto Luís12ORCID

Affiliation:

1. Department of Ophthalmology, Hospital de Santa Maria CHULN Lisbon Portugal

2. Visual Sciences Study Center, Faculty of Medicine University of Lisbon Lisbon Portugal

3. Department of Neurological Imaging, Hospital de Santa Maria CHULN Lisbon Portugal

4. Anatomy Institute, Faculty of Medicine University of Lisbon Lisbon Portugal

Abstract

AbstractPurposeTo evaluate bleb morphology features of different glaucoma drainage devices (GDD) using magnetic resonance imaging (MRI).Materials and MethodsProspective cohort study of GDD and bleb morphology in consecutive glaucoma patients implanted with Ahmed Glaucoma Valve (AGV), Paul Glaucoma Implant (PGI), Baerveldt Glaucoma Implant (BGI) and Ahmed ClearPath (ACP) devices. Thirty‐six eyes from 30 consecutive patients underwent standardized GDD implantation followed by MRI at least 1 month after surgery. Main outcomes included bleb volume and endplate position relative to the optic nerve. Secondary outcomes included intraocular pressure (IOP), medication and surgical complications during a 12‐month follow‐up.ResultsSeven eyes were implanted with the AGV (19%), 5 with BGI (14%), 16 with PGI (44%) and 8 with ACP (22%). MRI scans were obtained 85 ± 66 days after surgery. Mean total bleb volume was 563 ± 390 mm3. This bleb volume was inversely correlated with early post‐operative IOP (day 7; rs = −0.3326, p = 0.0475) but positively correlated with IOP at 12 months (rs = 0.3592, p = 0.0341). No significant difference in total bleb volume was found between GDD types (p = 0.1223). A double‐layered bleb was observed in 34 eyes (94%). The inferior bleb volume was significantly larger in PGI devices versus other GDD types (380 ± 205 vs. 193 ± 161 mm3; p = 0.0043). Distance from the endplate to the optic nerve was 9.5 ± 4.0 mm, similar across GDDs (p = 0.2519).ConclusionsDouble‐layered blebs are a common finding with GDDs. Bleb volume showed different correlations with IOP at distinct timepoints and the PGI device formed larger blebs. A standardized GDD implantation technique ensures a safe distance from the GDD endplate to the optic nerve.

Publisher

Wiley

Subject

Ophthalmology,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3