Internal validation of reduced PCR reaction volume of the Qiagen Investigator® Argus X‐12 QS Kit from blood samples on FTA cards

Author:

Alwi Aedrianee Reeza12,Mahat Naji Arafat34,Mohd Salleh Faezah1,Ishar Seri Mirianti5,Kamaluddin Mohammad Rahim6,Rashid Mohd Radzniwan A.7

Affiliation:

1. Department of Biosciences, Faculty of Science Universiti Teknologi Malaysia (UTM) Johor Bahru Malaysia

2. Department of Chemistry Malaysia Johor State Johor Bahru Malaysia

3. Department of Chemistry, Faculty of Science Universiti Teknologi Malaysia (UTM) Johor Bahru Malaysia

4. Centre for Sustainable Nanomaterials, Ibnu Sina Institute for Scientific and Industrial Research Universiti Teknologi Malaysia (UTM) Johor Bahru Malaysia

5. Forensic Science Program, Faculty of Health Sciences Universiti Kebangsaan Malaysia (UKM) Bangi Malaysia

6. Psychology and Human Well Being Research Centre, Faculty of Social Sciences and Humanities Universiti Kebangsaan Malaysia (UKM) Bangi Malaysia

7. Family Medicine Unit, Faculty of Medicine and Health Science Universiti Sains Islam Malaysia (USIM) Nilai Malaysia

Abstract

AbstractThe onus of proof in criminal cases is beyond any reasonable doubt, and the issue on the lack of complete internal validation data can be manipulated when it comes to justifying the validity and reliability of the X‐chromosomal short tandem repeats analysis for court representation. Therefore, this research evaluated the efficiency of the optimized 60% reduced volumes for polymerase chain reaction (PCR) amplification using the Qiagen Investigator® Argus X‐12 QS Kit, as well as the capillary electrophoresis (CE) sample preparation for blood samples on Flinder's Technology Associates (FTA) cards. Good‐quality DNA profile (3000–12,000 RFU) from the purified blood sample on FTA card (1.2 mm) were obtained using the optimized PCR (10.0 μL of PCR reaction volume and 21 cycles) and CE (9.0 μL Hi‐Di™ Formamide and 0.3 μL DNA Size Standard 550 [BTO] and 27 s injection time) conditions. The analytical and stochastic thresholds were 100 and 200 RFU, respectively. Hence, the internal validation data supported the use of the optimized 60% reduced PCR amplification reaction volume of the Qiagen Investigator® Argus X‐12 QS Kit as well as the CE sample preparation for producing reliable DNA profiles that comply with the quality assurance standards for forensic DNA testing laboratories, while optimizing the analytical cost.

Publisher

Wiley

Subject

Genetics,Pathology and Forensic Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3