Drusen‐aware model for age‐related macular degeneration recognition

Author:

Pan Junjun1,Ho Sharon23ORCID,Ly Angelica3ORCID,Kalloniatis Michael34ORCID,Sowmya Arcot1ORCID

Affiliation:

1. School of Computer Science and Engineering University of New South Wales Kensington New South Wales Australia

2. Centre for Eye Health University of New South Wales Kensington New South Wales Australia

3. School of Optometry and Vision Science University of New South Wales Kensington New South Wales Australia

4. School of Medicine (Optometry) Deakin University Waurn Ponds Victoria Australia

Abstract

AbstractIntroductionThe purpose of this study was to build an automated age‐related macular degeneration (AMD) colour fundus photography (CFP) recognition method that incorporates confounders (other ocular diseases) and normal age‐related changes by using drusen masks for spatial feature supervision.MethodsA range of clinical sources were used to acquire 7588 CFPs. Contrast limited adaptive histogram equalisation was used for pre‐processing. ResNet50 was used as the backbone network, and a spatial attention block was added to integrate prior knowledge of drusen features into the backbone. The evaluation metrics used were sensitivity, specificity and F1 score, which is the harmonic mean of precision and recall (sensitivity) and area under the receiver‐operating characteristic (AUC). Fivefold cross‐validation was performed, and the results compared with four other methods.ResultsExcellent discrimination results were obtained with the algorithm. On the public dataset (n = 6565), the proposed method achieved a mean (SD) sensitivity of 0.54 (0.09), specificity of 0.99 (0.00), F1 score of 0.62 (0.06) and AUC of 0.92 (0.02). On the private dataset (n = 1023), the proposed method achieved a sensitivity of 0.92 (0.02), specificity of 0.98 (0.01), F1 score of 0.92 (0.01) and AUC of 0.98 (0.01).ConclusionThe proposed drusen‐aware model outperformed baseline and other vessel feature‐based methods in F1 and AUC on the AMD/normal CFP classification task and achieved comparable results on datasets that included other diseases that often confound classification. The method also improved results when a five‐category grading protocol was used, thereby reflecting discriminative ability of the algorithm within a real‐life clinical setting.

Publisher

Wiley

Subject

Sensory Systems,Optometry,Ophthalmology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3