Is motor‐driven insertion of orthodontic miniscrews more advantageous than manual insertion? A micro‐CT evaluation of bone miniscrew contact surface area and cortical microcracks in rabbits

Author:

Alansari Reem A.1ORCID,Zawawi Khaled H.1ORCID,Vaiid Nikhillesh23ORCID,Natto Zuhair4,Adel Samar M.5ORCID,Alshihri Maha R.6,Alsadat Mohammed7,Dause Rania1,Agou Shoroog1,Hassan Ali H.2

Affiliation:

1. Department of Orthodontics, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia

2. Faculty of Dentistry National University of Singapore Singapore Singapore

3. Department of Orthodontics, Saveetha Dental College Saveetha Institute of Medical and Technical Sciences, Saveetha University Chennai India

4. Department of Dental Public Health, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia

5. Department of Orthodontics, Faculty of Dentistry Alexandria University Alexandria Egypt

6. Department of Pedodontics, Faculty of Dentistry King Abdulaziz University Jeddah Saudi Arabia

7. University Dental Hospital King Abdulaziz University Jeddah Saudi Arabia

Abstract

AbstractAimThis in vitro study aimed to evaluate and compare the bone–miniscrew contact surface area (BMC) and the cortical bone microcracks (CM) resulting from manual (hand‐driven) and automated (motor‐driven) orthodontic miniscrew (OM) insertion methods.MethodsThirty‐three OM were inserted in the femurs of nine New Zealand rabbits using manual (n = 16) and automated (n = 17) insertions. After euthanizing the rabbits, bone blocks, each including one OM, were sawed. Micro‐CT scanning was performed, and data analysis included reconstruction, binarization and quantification of morphometric parameters of BMC and the number and length of CM. Means and standard deviations for complete BMC, complete BMC proportion, cortical BMC, cortical BMC proportion, and length and number of CM were calculated. Mixed model analysis was used to adjust for more than one sample/CM per animal. A paired t‐test was used to compare the number of CM between the two groups.ResultsCompared to the automated insertion, manually inserted miniscrews had significantly lower complete BMC (7.54 ± 1.80 mm2 vs. 11.99 ± 3.64 mm2), cortical BMC (5.91 ± 1.48 mm2 vs. 8.48 ± 1.90 mm2) and cortical BMC proportion (79.44 ± 5.84% vs. 87.94 ± 3.66%). However, it was not statistically significant in complete BMC proportion (p = .052). The automated insertion also resulted in a significantly lower mean number of CM than the manual method (p = .012). However, the length of the cracks was shorter in the manual group but with no significant difference (p = 0.256).ConclusionMotor‐driven OM insertion results in superior BMC and reduction in the number of CM, which may lead to better miniscrew stability.

Funder

King Abdulaziz University

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3