Transthoracic echocardiographic Doppler metrics in evaluating bioprosthetic tricuspid valve dysfunction

Author:

Zhang Xin123,Peng Lingli123,Fang Lingyun123,Xu Jia123ORCID,Wang Jing123ORCID,Sun Wei123,Gao Tang123,Li Yuman123,Zhang Li123ORCID,Lv Qing123ORCID,Xie Mingxing123ORCID,Wu Wenqian123ORCID

Affiliation:

1. Department of Ultrasound Medicine Union Hospital, Tongji Medical College, Huazhong University of Science and Technology Wuhan China

2. Hubei Province Clinical Research Center for Medical Imaging Wuhan China

3. Hubei Province Key Laboratory of Molecular Imaging Wuhan China

Abstract

AbstractPurposeThere is currently limited information on the utility of transthoracic echocardiography (TTE)‐derived Doppler parameters for assessing bioprosthetic tricuspid valve (BTV) dysfunction. Our study aimed to establish the precision and appropriate reference ranges for routinely collected transthoracic Doppler parameters in the assessment of BTV dysfunction.MethodsWe retrospectively evaluated 100 BTV patients who underwent TTE. Based on redo surgical confirmation or more than 2 repeat TTE or transesophageal echocardiography (TEE) examinations, patients were allocated to normal (n = 61), regurgitant (n = 24), or stenotic (n = 15) BTV group. Univariate and multivariate binary logistic regression were performed to identify TTE Doppler parameters that detected BTV dysfunction.ResultsThe VTI ratio (VTITV/VTILVOT) was the most accurate Doppler parameter for detecting BTV dysfunction, with a ratio of >2.8 showing 84.6% sensitivity and 90.2% specificity. VTI ratio > 3.2, mean gradient (MGTV) > 6.2 mmHg and pressure half‐time > 218 ms detected significant BTV stenosis, with sensitivities of 100%, 93.3% and 93.3% and specificities of 82.4%, 75.3% and 87.1%, respectively. After multivariate analysis, the VTI ratio > 2.8 (OR = 9.00, 95% CI = 2.13–41.61, = .003) and MGTV > 5.1 mmHg (OR = 6.50, 95% CI = 1.69–27.78, = .008) were the independent associations of BTV dysfunction. With these cutoff values, 75.0%–92.2% of normal and 62.5%–96.0% of dysfunctional BTV were identified.ConclusionsDoppler parameters from TTE can accurately identify BTV dysfunction, particularly with VTI ratio > 2.8 and MGTV > 5.1 mmHg, to assess the need for additional testing with TEE.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3