Evaluating keratometry and corneal astigmatism data from biometers and anterior segment tomographers and mapping to reconstructed corneal astigmatism

Author:

Langenbucher Achim1ORCID,Taroni Leonardo2,Coutinho Catarina P.3,Cayless Alan4,Szentmáry Nóra5,Hoffmann Peter6,Wendelstein Jascha17ORCID,Savini Giacomo8

Affiliation:

1. Department of Experimental Ophthalmology Saarland University Homburg Germany

2. Department of Ophthalmology Morgagni‐Pierantoni Hospital Forlì Italy

3. Ophthalmology Studio Oculistico d'Azeglio Bologna Italy

4. School of Physical Sciences The Open University Milton Keynes UK

5. Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research Saarland University Homburg Germany

6. Augenklinik Augen‐ und Laserklinik Castrop‐Rauxel Castrop‐Rauxel Germany

7. Department of Ophthalmology Johannes Kepler University Linz Austria

8. Ophthalmology IRCCS Bietti Foundation Rome Italy

Abstract

AbstractBackgroundTo compare results from different corneal astigmatism measurement instruments; to reconstruct corneal astigmatism from the postimplantation spectacle refraction and toric intraocular lens (IOL) power; and to derive models for mapping measured corneal astigmatism to reconstructed corneal astigmatism.MethodsRetrospective single centre study involving 150 eyes treated with a toric IOL (Alcon SN6AT, DFT or TFNT). Measurements included IOLMaster 700 keratometry (IOLMK) and total keratometry (IOLMTK), Pentacam keratometry (PK) and total corneal refractive power in 3 and 4 mm zones (PTCRP3 and PTCRP4), and Aladdin keratometry (AK). Regression‐based models mapping the measured C0 and C45 components (Alpin's method) to reconstructed corneal astigmatism were derived.ResultsMean C0 components were 0.50/0.59/0.51 dioptres (D) for IOLMK/PK/AK; 0.2/0.26/0.31 D for IOLMTK/PTCRP3/PTCRP4; and 0.26 D for reconstructed corneal astigmatism. All corresponding C45 components ranged around 0. The prediction models had main diagonal elements lower than 1 with some crosstalk between C0 and C45 (nonzero off‐diagonal elements). Root‐mean‐squared residuals were 0.44/0.45/0.48/0.51/0.50/0.47 D for IOLMK/IOLMTK/PK/PTCRP3/PTCRP4/AK.ConclusionsResults from the different modalities are not consistent. On average IOLMTK/PTCRP3/PTCRP4 match reconstructed corneal astigmatism, whereas IOLMK/PK/AK show systematic C0 offsets of around 0.25 D. IOLMTK/PTCRP3/PTCRP4. Prediction models can reduce but not fully eliminate residual astigmatism after toric IOL implantation.

Publisher

Wiley

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3