The microbial contamination of pressurised metered-dose inhalers anonymously sourced from the South-East Queensland Australia community population

Author:

Borovina Leigh R1,Tremellen Kate E1,Walker Monique P1,Hawley Tegan M1,Horgan Anthony R1,Grant Gary D1,King Michelle A1

Affiliation:

1. School of Pharmacy, Gold Coast campus, Griffith University, Gold Coast, QLD, Australia

Abstract

Abstract Objectives To provide preliminary evidence regarding the presence, identity and level of microbial contamination of metered-dose inhalers sourced from the community. To correlate the level of microbial colonisation to the visible presence of debris on the interior and exterior surface of the device mouthpiece. Methods In this exploratory study, 45 post-use de-identified pressurised metered-dose inhalers were collected from the South-East Queensland Australian community. Prior to swabbing, the presence of visible debris on the internal and external surfaces of the mouthpiece was recorded for each device. Swabs taken from external and inner surfaces of the mouthpiece of each device were streaked onto standard growth media for colony counts. Individual colonies were selected and enriched then streaked onto a range of differential and chromogenic media for differential identification. Key findings A total of 36 post-use pressurised metered dose inhalers (80%) were shown to be colonised by microbes relative to unused devices (P = 0.01). Devices were primarily colonised by common respiratory flora, including Staphylococcus, Streptococcus and Haemophilus species. Of greatest concern was the positive identification of methicillin-resistant Staphylococcus aureus (18%) and extended-spectrum β-lactamase-producing Enterobacteriaceae (7%), Pseudomonas aerugonisa (2%) and Candida species (9%). The level of internal microbial contamination appeared to correlate to the presence of visible debris on the inside of the inhaler mouthpiece (P = 0.06) but not external debris (P = 0.59) while external contamination was not associated with internal (P = 0.99) or external debris (P = 0.63). Conclusions These preliminary data suggest that pressurised metered dose inhalers are potential reservoirs for bacteria. While this study was not aimed at determining the impact that contaminated pressurised metered-dose inhalers may have on the user, future research is being conducted to address the implications of these findings and the consequences they may have for the population of users.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Health Policy,Pharmaceutical Science,Pharmacy

Reference12 articles.

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3