Affiliation:
1. Lilly Research Centre Ltd., Erl Wood Manor, Windlesham, Surrey, UK
Abstract
Abstract
The load necessary to fracture lactose monohydrate tablets under diametral compression has been determined using an Instron physical testing instrument, so that true tensile failure was obtained in all cases, leading to improved reproducibility. Four ranges of tablet thickness were examined at 12·7 mm diameter. All tablets gave a linear increase of breaking load with compaction pressure up to 310 MN/m2. Expressing the tablet strength as the breaking load gave a separate regression line for each range of tablet thickness, whereas the use of tensile strength provided a common regression line, within given statistical limits, for all but the lowest range of tablet thickness. The fact that such a correlation is possible shows that the tensile strength is a property of the “as compacted” material and provides a new and useful parameter to maintain constancy of properties when tablet size is changed.
Publisher
Oxford University Press (OUP)
Subject
Pharmaceutical Science,Pharmacology
Cited by
83 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献