Affiliation:
1. School of Pharmacy, Curtin University of Technology, PO Box U1987, Perth, Western Australia 6001
Abstract
Abstract
Analytical methods have been developed which enable phenylmercuric nitrate, mercuric ion and diphenylmercury to be measured in sulphacetamide drops. Application of these methods demonstrate that during heat sterilization of both 10 and 30% sulphacetamide drops containing phenylmercuric nitrate, together with disodium edetate and sodium metabisulphite, there is a 20–30% overall loss of phenylmercuric nitrate. This loss occurs mainly due to the phenylmercuric ion establishing an equilibrium with equimolar amounts of mercuric ion and diphenylmercury.
Publisher
Oxford University Press (OUP)
Subject
Pharmaceutical Science,Pharmacology
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Pancrelipase (Pancreatic Enzymes) – Piroxicam;Trissel’s Stability of Compounded Formulations, 6e;2018-03
2. Preservatives for Topical Ocular Drug Formulations;Pharmacology of Ocular Therapeutics;2016