Spatial correlation of left atrial low voltage substrate in sinus rhythm versus atrial fibrillation: The rhythm specificity of atrial low voltage substrate

Author:

Nairn Deborah1,Eichenlaub Martin23,Lehrmann Heiko23,Müller‐Edenborn Björn23,Chen Juan23,Huang Taiyuan23,Nagel Claudia1,Sánchez Jorge1,Luongo Giorgio1,Westermann Dirk23,Arentz Thomas23,Dössel Olaf1,Jadidi Amir234,Loewe Axel1ORCID

Affiliation:

1. Institute of Biomedical Engineering, Karlsruhe Institute of Technology (KIT) Karlsruhe Germany

2. Department of Cardiology and Angiology, Medical Center University of Freiburg Freiburg Germany

3. Faculty of Medicine University of Freiburg Freiburg Germany

4. Arrhythmia Division, Department of Cardiology Heart Center Lucerne, Lucerne Cantonal Hospital Lucerne Switzerland

Abstract

AbstractIntroductionImproved sinus rhythm (SR) maintenance rates have been achieved in patients with persistent atrial fibrillation (AF) undergoing pulmonary vein isolation plus additional ablation of low voltage substrate (LVS) during SR. However, voltage mapping during SR may be hindered in persistent and long‐persistent AF patients by immediate AF recurrence after electrical cardioversion. We assess correlations between LVS extent and location during SR and AF, aiming to identify regional voltage thresholds for rhythm‐independent delineation/detection of LVS areas. (1) Identification of voltage dissimilarities between mapping in SR and AF. (2) Identification of regional voltage thresholds that improve cross‐rhythm substrate detection. (3) Comparison of LVS between SR and native versus induced AF.MethodsForty‐one ablation‐naive persistent AF patients underwent high‐definition (1 mm electrodes; >1200 left atrial (LA) mapping sites per rhythm) voltage mapping in SR and AF. Global and regional voltage thresholds in AF were identified which best match LVS < 0.5 mV and <1.0 mV in SR. Additionally, the correlation between SR‐LVS with induced versus native AF‐LVS was assessed.ResultsSubstantial voltage differences (median: 0.52, interquartile range: 0.33–0.69, maximum: 1.19 mV) with a predominance of the posterior/inferior LA wall exist between the rhythms. An AF threshold of 0.34 mV for the entire left atrium provides an accuracy, sensitivity and specificity of 69%, 67%, and 69% to identify SR‐LVS < 0.5 mV, respectively. Lower thresholds for the posterior wall (0.27 mV) and inferior wall (0.3 mV) result in higher spatial concordance to SR‐LVS (4% and 7% increase). Concordance with SR‐LVS was higher for induced AF compared to native AF (area under the curve[AUC]: 0.80 vs. 0.73). AF‐LVS < 0.5 mV corresponds to SR‐LVS < 0.97 mV (AUC: 0.73).ConclusionAlthough the proposed region‐specific voltage thresholds during AF improve the consistency of LVS identification as determined during SR, the concordance in LVS between SR and AF remains moderate, with larger LVS detection during AF. Voltage‐based substrate ablation should preferentially be performed during SR to limit the amount of ablated atrial myocardium.

Publisher

Wiley

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3