Comparison of cystatin C‐based estimated glomerular filtration rate with measured glomerular filtration rate in a pediatric cohort of patients with chronic kidney disease

Author:

Lindvig Tilde Ostendorf12ORCID,Simonsen Jane Angel23ORCID,Gerke Oke23ORCID,Thiesson Helle Charlotte12ORCID

Affiliation:

1. Department of Nephrology Odense University Hospital Odense Denmark

2. Department of Clinical Research University of Southern Denmark Odense Denmark

3. Department of Nuclear Medicine University of Southern Denmark Odense Denmark

Abstract

AbstractBackgroundIt is essential to have an accurate assessment of the renal function of patients with chronic kidney disease to monitor, treat, and predict further development of the condition. Measurement of renal function in terms of glomerular filtration rate (GFR) requires either urine or blood sampling, but especially in children, more simple methods of measurement are preferable. The main objective of this study was to examine if the estimated GFR (eGFR) calculated with different cystatin‐C‐based equations was comparable to the GFR measured by a radiotracer (mGFR) in pediatric patients.MethodsIn this retrospective study, 28 pediatric patients contributed with 73 pairs of measurements collected within 5 years. Bland–Altman Limits of Agreement were used to evaluate the performance and accuracy of two different cystatin‐C‐based estimates, the CKiDCrea‐CysC and the CKiDU25 respectively, compared to an mGFR based on plasma clearance of technetium‐99m‐diethylenetriaminepentaacetic acid or chromium‐51‐ethylenediaminetetraacetic acid.ResultsUsing the CKiDCrea‐CysC equation, 58.9% of the datasets were within P10 and 87.7% were within P30. The mean difference was 4.8 mL/min/1.73m2 (standard deviation: 8.5 mL/min/1.73m2) and tended to overestimate GFR and thereby overrate the kidney function within the entire GFR range. Using the CKiDU25 equation, 53.4% were within P10 and 93.2% within P30. The mean difference was −2.9 mL/min/1.73m2 (standard deviation: 8.4 mL/min/1.73m2), but the difference varied with the GFR value.ConclusionsA cystatin‐C‐based eGFR provides a viable substitute for monitoring renal function in pediatric patients with chronic kidney disease. However, it has a lower accuracy than mGFR and can therefore not replace mGFR in clinical use.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3