Integrated pulmonary index during procedural sedation and analgesia: A cluster‐randomized trial

Author:

Conway Aaron123ORCID,Goudarzi Rad Mohammad23ORCID,Chang Kristina23,Parotto Matteo45,Mafeld Sebastian6

Affiliation:

1. School of Nursing Queensland University of Technology Brisbane Queensland Australia

2. Lawrence S. Bloomberg Faculty of Nursing University of Toronto Toronto Ontario Canada

3. Peter Munk Cardiac Centre University Health Network Toronto Ontario Canada

4. Department of Anesthesiology and Pain Medicine and Interdepartmental Division of Critical Care Medicine University of Toronto Toronto Ontario Canada

5. Department of Anesthesia and Pain Management University Health Network Toronto Ontario Canada

6. Joint Department of Medical Imaging University Health Network Toronto Ontario Canada

Abstract

AbstractAimTo evaluate the effectiveness of utilizing the integrated pulmonary index for capnography implementation during sedation administered by nurses.DesignCluster‐randomized trial.MethodsParticipants were enrolled from the interventional radiology department at an academic hospital in Canada. Nurses were randomized to either enable or disable the Integrated Pulmonary Index feature of the capnography monitor. Procedures were observed by a research assistant to collect information about alarm performance characteristics. The primary outcome was the number of seconds in an alert condition state without an intervention being applied.ResultsThe number of seconds in an alarm state without intervention was higher in the group that enabled the integrated pulmonary index compared to the group that disabled this feature, but this difference did not reach statistical significance. Likewise, the difference between groups for the total alarm duration, total number of alarms and the total number of appropriate alarms was not statistically significant. The number of inappropriate alarms was higher in the group that enabled the Integrated Pulmonary Index, but this estimate was highly imprecise. There was no difference in the odds of an adverse event (measured by the Tracking and Reporting Outcomes of Procedural Sedation tool) occurring between groups. Desaturation events were uncommon and brief in both groups but the area under the SpO2 90% desaturation curve scores were lower for the group that enabled the integrated pulmonary index.ConclusionEnabling the integrated pulmonary index during nurse‐administered procedural sedation did not reduce nurses' response times to alarms. Therefore, integrating multiple physiological parameters related to respiratory assessment into a single index did not lower the threshold for intervention by nurses.Implications for the Profession and/or Patient CareThe time it takes to respond to capnography monitor alarms will not be reduced if the integrated pulmonary Iindex feature of capnography monitors is enabled during nurse‐administered procedural sedation.ImpactResults do not support the routine enabling of the integrated pulmonary index when nurses use capnography to monitor patients during procedural sedation as a strategy to reduce the time it takes to initiate responses to alarms.Reporting MethodCONSORT.Patient or Public ContributionThere was no patient or public contribution.Trial RegistrationThis study was prospectively registered at ClinicalTrials.gov (ID: NCT05068700).

Funder

Medtronic

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3