Affiliation:
1. Santa Rita Cassia Hospital Vitoria Espirito Santo Brazil
2. Santa Casa Misericordia Hospital Vitória Espirito Santo Brazil
3. Cardiology Division of Ribeirao Preto Medical School – University of Sao Paulo Ribeirao Preto Sao Paulo Brazil
Abstract
AbstractIntroductionLesion size index (LSI) was introduced with the use of Tacticath™ and as a surrogate of lesion quality. The metric used to achieve the predetermined values involves combined information of contact force (CF), power and radiofrequency time. Rapid atrial pacing (RAP) and high‐frequency low‐tidal volume ventilation (HFLTV) independently or in combination improve catheter stability and CF and quality of lesions. Data of the impact of body weight adjusted HFLTV ventilation strategy associated with RAP in the lesion metrics still lacking. The study aimed to compare the results of high‐power short‐duration (HPSD) atrial fibrillation ablation using simultaneous weight adjusted HFLTV and RAP and standard ventilation (SV) protocol.MethodsProspective, nonrandomized study with 136 patients undergoing de novo ablation divided into two groups; 70 in RAP (100 ppm) + HFLTV with 4 mL/kg of tidal volume and 25 breaths/min (group A) and 66 patients with SV in intrinsic sinus rhythm (group B). Ablation using 50 W, CF of 5–10 g/10–20 g and 40 mL/minute flow rate on the posterior and anterior left atrial wall, respectively.ResultsNo procedure‐related complications. Group A: Mean LSI points 70 ± 16.5, mean total lower LSI 3.4 ± 0.5, mean total higher LSI 8.2 ± 0.4 and mean total LSI 5.6 ± 0.6. Anterior and posterior wall mean total LSI was 6.0 ± 0.4 and 4.2 ± 0.3, respectively. Mean local impedance drop (LID) points were 118.8 ± 28.4, mean LID index (%) 12.9 ± 1.5, and mean LID < 12% points 55.9 ± 23.8. Anterior and posterior wall mean total LID index were 13.6 ± 2.0 and 11.9 ± 1.7, respectively. Recurrence in 11 (15.7%) patients. Group B: Mean LSI points 56 ± 2.7, mean total lower LSI 2.9 ± 0.7, mean total higher LSI 6.9 ± 0.9, and mean total LSI 4.8 ± 0.8. Anterior and posterior wall mean total LSI was 5.1 ± 0.3 and 3.5 ± 0.5, respectively. Mean LID points were 111.4 ± 21.5, mean LID index (%) 11.4 ± 1.2, and mean LID < 12% points 54.9 ± 25.2. Anterior and posterior wall mean total LID index were 11.8 ± 1.9 and 10.3 ± 1.7, respectively. Recurrence in 14 (21.2%) patients. Mean follow up was 15.2 ± 4.4 months.ConclusionWeight adjusted HFLTV ventilation with RAP HPSD ablation produced lower recurrence rate and better LSI and LID parameters in comparison to SV and intrinsic sinus rhythm.