Corneal biomechanics are not exclusively compromised in high myopia

Author:

Yii Fabian12ORCID,Strang Niall3,Bernabeu Miguel O.45,Dhillon Baljean126,MacGillivray Tom12

Affiliation:

1. Centre for Clinical Brain Sciences The University of Edinburgh Edinburgh UK

2. Curle Ophthalmology Laboratory, Institute for Regeneration and Repair The University of Edinburgh Edinburgh UK

3. Department of Vision Sciences Glasgow Caledonian University Glasgow UK

4. Centre for Medical Informatics, Usher Institute The University of Edinburgh Edinburgh UK

5. The Bayes Centre The University of Edinburgh Edinburgh UK

6. Princess Alexandra Eye Pavilion, NHS Lothian Edinburgh UK

Abstract

AbstractIntroductionResearch assuming linearity has concluded that corneal biomechanics are compromised in high myopia. We investigated whether this assumption was appropriate and re‐examined these associations across different levels of myopia.MethodsMyopic (spherical equivalent refraction, SER ≤ −0.50 D) eyes of 10,488 adults aged 40–69 years without any history of systemic and ocular conditions were identified in the UK Biobank. Ordinary least squares (OLS) regression was employed to test the linear association between corneal hysteresis (CH) or corneal resistance factor (CRF), separately, and SER while controlling for age, sex, corneal radius and intraocular pressure. Quantile regression (QR) was used to test the same set of associations across 49 equally spaced conditional quantiles of SER.ResultsIn OLS regression, each standard deviation (SD) decrease in CH and CRF was associated with 0.08 D (95% CI: 0.04–0.12; p < 0.001) and 0.10 D (95% CI: 0.04–0.15; p < 0.001) higher myopia, respectively. However, residual analysis indicated that the linearity assumption was violated. QR revealed no evidence of a significant association between CH/CRF and SER in low myopia, but a significant (p < 0.05) positive association became evident from −2.78 D (0.06 and 0.08 D higher myopia per SD decrease in CH and CRF). The magnitude of association increased exponentially with increasing myopia: in the −5.03 D quantile, every SD decrease in CH and CRF was associated with 0.17 D (95% CI: 0.08–0.25; p < 0.001) and 0.21 D (95% CI: 0.10–0.31; p < 0.001) higher myopia. In the −8.63 D quantile, this further increased to 0.54 D (95% CI: 0.33–0.76; p < 0.001) and 0.67 D (95% CI: 0.41–0.93; p < 0.001) higher myopia per SD decrease in CH and CRF.ConclusionsCorneal biomechanics appeared compromised from around −3.00 D. These changes were observed to be exponential with increasing myopia.

Funder

Medical Research Council

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Retinal Changes From Hyperopia to Myopia: Not All Diopters Are Created Equal;Investigative Ophthalmology & Visual Science;2024-05-17

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3