Effect of impeller rotational phase on the FDA blood pump velocity fields

Author:

Ucak Kagan1ORCID,Karatas Faruk1,Pekkan Kerem1ORCID

Affiliation:

1. Mechanical Engineering Department Koc University Istanbul Turkey

Abstract

AbstractBackgroundThe Food and Drug Administration (FDA) blood pump is an open‐source benchmark cardiovascular device introduced for validating computational and experimental performance analysis tools. The time‐resolved velocity field for the whole impeller has not been established, as is undertaken in this particle image velocimetry (PIV) study. The level of instantaneous velocity fluctuations is important, to assess the flow‐induced rotor vibrations which may contribute to the total blood damage.MethodsTo document these factors, time‐resolved two‐dimensional PIV experiments were performed that were precisely phase‐locked with the impeller rotation angle. The velocity fields in the impeller and in the volute conformed with the previous single blade passage experiments of literature.ResultsDepending on the impeller orientation, present experiments showed that volute outlet nozzle flow can fluctuate up to 34% during impeller rotation, with a maximum standard experimental uncertainty of 2.2%. Likewise, the flow fields in each impeller passage also altered in average 33.5%. Considerably different vortex patterns were observed for different blade passages, with the largest vortical structures reaching an average core radii of 7 mm. The constant volute area employed in the FDA pump design contributes to the observed velocity imbalance, as illustrated in our velocity measurements.ConclusionsBy introducing the impeller orientation parameter for the nozzle flow, this study considers the possible uncertainties influencing pump flow. Expanding the available literature data, analysis of inter‐blade relative velocity fields is provided here for the first‐time to the best of our knowledge. Consequently, our research fills a critical knowledge gap in the understanding of the flow dynamics of an important benchmark cardiovascular device. This study prompts the need for improved hydrodynamic designs and optimized devices to be used as benchmark test devices, to build more confidence and safety in future ventricular assist device performance assessment studies.

Funder

H2020 European Research Council

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3