1. Department of Laboratory Medicine The First Affiliated Hospital of Soochow University Suzhou Jiangsu China
Abstract
AbstractBackgroundThe erythrocyte sedimentation rate (ESR) is a nonspecific inflammatory indicator and is widely used in clinical diagnosis. Westergren is the gold standard method recommended by the International Committee for Standardization of Hematology (ICSH), but it is time‐consuming and inconvenient and has biosafety risks. A new alternate method for ESR (Easy‐W ESR) measurement was designed and integrated into the Mindray BC‐720 series automated hematology analyzer to meet the clinical needs of hematology laboratories for efficiency, safety, and automation. In this study, the performance of the new ESR method was evaluated based on the ICSH recommendations on modified and alternate ESR methods.MethodsMethodological comparisons using the BC‐720 analyzer, TEST 1, and the Westergren method were performed to assess repeatability, carryover, sample stability, reference range validation, factors influencing the ESR, and clinical applicability in rheumatology and orthopedics.ResultsThe correlation between the BC‐720 analyzer and the Westergren method was good (Y = 2.082 + 0.9869X, r = 0.9657, P > 0.0001, n = 342), carryover was <1%, the repeatability standard deviation was ≤1 mm/h, and the coefficient of variation (CV) was ≤5%. The reference range meets the manufacturer's claim. For rheumatology patients, the BC‐720 analyzer showed a good correlation with the Westergren method (Y = 1.021X–1.941, r = 0.9467, n = 149). For orthopedic patients, the BC‐720 analyzer also showed a good correlation with the Westergren method (Y = 1.037X + 0.981, r = 0.978, n = 97).ConclusionThis study verified the clinical and analytical performance of the new ESR method, indicating that the results are very similar to those obtained using the Westergren method.
Subject
Biochemistry (medical),Clinical Biochemistry,Hematology,General Medicine
Reference39 articles.
1. Edmund Biernacki (1866-1911): Discoverer of the erythrocyte sedimentation rate. On the 100th anniversary of his death
2. The forgotten contribution of Dr. Edmund Faustyn Biernacki (1866‐1911) to the discovery of the erythrocyte sedimentation rate;Kucharz EJ;J Lab Clin Med,1988
3. Über die Ursachen der verminderten Suspensionsstabilität der Blutkörperchen während der Schwangerschaft;Fåhraeus R;Biochem Z,1918
4. Studies of the Suspension Stability of the Blood in Pulmonary Tuberculosis1
5. The Erythrocyte Sedimentation Rate: Old and New Clinical Applications
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Measurement System for Blood Sedimentation Rate Through Impedenzimetric Sampling;2024 IEEE International Symposium on Medical Measurements and Applications (MeMeA);2024-06-26