The combination of emicizumab and recombinant factor VIII in plasma: Which assays can we use for accurate measurement?

Author:

Bowyer Annette E.1ORCID,Maclean Rhona M.1,Kitchen Steve1ORCID

Affiliation:

1. Department of Coagulation, Royal Hallamshire Hospital Sheffield Teaching Hospital NHS Foundation Trust Sheffield UK

Abstract

AbstractIntroductionThe bispecific antibody, emicizumab, is a prophylactic therapy used for the treatment of haemophilia A (HA). Patients may require additional replacement factor VIII (FVIII) to ensure adequate haemostasis. This study investigated the laboratory measurement of severe HA (SHA) plasma spiked with 36 combinations of emicizumab plus recombinant (r) FVIII concentrates.MethodFVIII assays were performed by one stage assay (OSA) using eight APTT reagents from three manufacturers and chromogenic assays (CSA) using seven kits. CSA kits comprised a range of bovine FX/FIXa, bovine FX/human FIXa or human FX/FIXa. Thrombin generation (TG) was assessed by CAT and ST‐Genesia.ResultsEmicizumab‐calibrated modified OSA and human FX CSA both overestimated rFVIII in the presence of emicizumab; median FVIII:C of up to 89% higher was observed in plasma spiked with both drugs compared to just rFVIII. In bovine FX CSA assays, there was a FVIII:C increase of up to 11% in plasmas spiked with both drugs compared to rFVIII alone. TG parameters were not all normalized by the presence of emicizumab however addition of rFVIII increased TG. ETP and peak thrombin were normalized at 50 μg/ml emicizumab using ST‐Genesia but were still reduced at 75 μg/ml with CAT. Addition of rFVIII further normalized results.ConclusionModified OSA and human FX CSA could not distinguish between rFVIII or emicizumab. The presence of both emicizumab and rFVIII increased thrombin generation to normal levels compared to each drug alone. Bovine FX CSA can be used to accurately determine FVIII activity of rFVIII in plasma which also contains emicizumab.

Funder

Roche

Publisher

Wiley

Subject

Biochemistry (medical),Clinical Biochemistry,Hematology,General Medicine

Reference34 articles.

1. Emicizumab, a bispecific antibody recognizing coagulation factors IX and X: how does it actually compare to factor VIII?

2. Effects of emicizumab on APTT, one‐stage and chromogenic assays of factor VIII in artificially spiked plasma and in samples from haemophilia A patients with inhibitors

3. Laboratory coagulation tests and emicizumab treatment A United Kingdom Haemophilia Centre Doctors' Organisation guideline

4. Evaluation of emicizumab calibrator and controls with a modified one‐stage FVIII assay on an automated coagulation analyser;Shinohara S;Res Pract Thromb Haemost,2019

5. Laboratory measurement of emicizumab requires a product specific calibrator (PB1190);Wilmot HV;Res Pract Thromb Haemost,2019

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Diagnosis and laboratory monitoring of hemophilia A;Hematology;2023-12-08

2. Laboratory response to paradigm change in hemophilia treatment;Clinical Chemistry and Laboratory Medicine (CCLM);2023-06-15

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3