Stability and comparison of complete blood count parameters between capillary and venous blood samples

Author:

Doeleman Martijn J. H.12ORCID,Esseveld Anouk12,Huisman Albert23ORCID,de Roock Sytze12,Tiel Groenestege Wouter M.23

Affiliation:

1. Pediatric Immunology and Rheumatology, Division of Pediatrics University Medical Center Utrecht Utrecht The Netherlands

2. Faculty of Medicine Utrecht University Utrecht The Netherlands

3. Central Diagnostic Laboratory University Medical Center Utrecht Utrecht The Netherlands

Abstract

AbstractIntroductionThis study assessed the comparability of complete blood count (CBC) parameters between capillary and venous samples, and extended previous research by examining the influence of different storage temperatures on CBC stability up to 7 days after sample collection.MethodsVenous and capillary blood samples were collected from 93 adult patients. Hemoglobin (Hb), hematocrit (Ht), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), mean platelet volume (MPV), leukocytes, lymphocytes, basophils, eosinophils, erythrocytes, red cell distribution width (RDW), immature granulocytes (IG), immature reticulocyte fraction (IRF), monocytes, neutrophils, platelets, and reticulocytes were measured. Deming regression and mean relative differences between venous and capillary measurements were contrasted with desirable total allowable error (TEa). Stability was assessed in 20–27 venous blood samples stored at 4, 21–22, or 30°C, and analyzed at 0, 24, 48, 72, 96, 120, 144, and 168 h. Mean relative change with respect to baseline measurements was compared to the desirable TEa to determine acceptable stability.ResultsDeming regression demonstrated strong linear correlations and acceptable variation between venous and capillary measurements. Erythrocytes, Hb, Ht, MCH, MCV, RDW, reticulocytes, and platelets showed acceptable stability for at least 96 h at 4°C. Mean relative change exceeded desirable TEa after 24 h at 30°C for all parameters, except erythrocytes, Hb, leukocytes, and MCH.ConclusionClinical laboratory specialists and clinicians should be aware of potential differences between venous and capillary measurements, and the influence of storage conditions. Clinical validity of delayed CBC analysis depends on the clinical situation and required precision of the result.

Publisher

Wiley

Subject

Biochemistry (medical),Clinical Biochemistry,Hematology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3