Technical notes on peripheral refraction, peripheral eye length and retinal shape determination

Author:

Atchison David A.1ORCID,Rozema Jos J.23ORCID

Affiliation:

1. Centre for Vision and Eye Research Queensland University of Technology Brisbane Queensland Australia

2. Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences Antwerp University Wilrijk Belgium

3. Department of Ophthalmology Antwerp University Hospital Edegem Belgium

Abstract

AbstractPurposeTo give an overview of the misconceptions and potential artefacts associated with measuring peripheral refractive error and eye length, the use of these measures to determine the retinal shape and their links to myopia development. Several issues were identified: the relationship between peripheral refractive error and myopia development, inferring the retinal shape from peripheral refraction or eye length patterns, artefacts and accuracy when measuring peripheral eye length using an optical biometer.MethodsA theory was developed to investigate the influence of artefacts in measuring peripheral eye length and on using peripheral eye length to make inferences about retinal shape.ResultsWhen determining peripheral axial length, disregarding the need to realign instruments with mounted targets can lead to incorrect field angles and positions of mounted targets by more than 10% for targets placed close to the eye. Peripheral eye length is not a good indicator of the effects of myopia or of treatment for myopia development because eyes of different lengths but with the same retinal shape would be interpreted as having different retinal shapes; the measurement leads to overestimates of changes in retinal curvature as myopia increases. Determining peripheral eye length as a function of estimated retinal height rather than field angle will halve the magnitude of the artefact. The artefact resulting from the peripheral use of biometers with an on‐axis calibration is modest and can be ignored.ConclusionThere are significant issues with peripheral measurements of the refractive error and eye length that must be considered when interpreting these data for myopia research. Some of these issues can be mitigated, while others require further investigation.

Publisher

Wiley

Subject

Sensory Systems,Optometry,Ophthalmology

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3