Comparison of T1‐weighted landmark placement and ROI transfer onto diffusion‐weighted EPI sequences for targeted tractography tasks in the optic nerve

Author:

Janko Markus1ORCID,Santaniello Sascha D.1,Brockmann Carolin1,Wolf Marcel1,Grauhan Nils F.1,Schöffling Vanessa I.1,Dimova Violeta2,Ponto Katharina3,Hoffmann Esther M.3,Kleinekofort Wolfgang4,Othman Ahmed E.1,Brockmann Marc A.1,Kronfeld Andrea1

Affiliation:

1. Department of Neuroradiology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany

2. Department of Neurology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany

3. Department of Ophthalmology University Medical Center of the Johannes Gutenberg‐University Mainz Mainz Germany

4. Applied Physics & Medical Engineering, Hochschule RheinMain Rüsselsheim Germany

Abstract

AbstractDiffusion‐based tractography in the optic nerve requires sampling strategies assisted by anatomical landmark information (regions of interest [ROIs]). We aimed to investigate the feasibility of expert‐placed, high‐resolution T1‐weighted ROI‐data transfer onto lower spatial resolution diffusion‐weighted images.Slab volumes from 20 volunteers were acquired and preprocessed including distortion bias correction and artifact reduction. Constrained spherical deconvolution was used to generate a directional diffusion information grid (fibre orientation distribution‐model [FOD]). Three neuroradiologists marked landmarks on both diffusion imaging variants and structural datasets. Structural ROI information (volumetric interpolated breath‐hold sequence [VIBE]) was respectively registered (linear with 6/12 degrees of freedom [DOF]) onto single‐shot EPI (ss‐EPI) and readout‐segmented EPI (rs‐EPI) volumes, respectively. All eight ROI/FOD‐combinations were compared in a targeted tractography task of the optic nerve pathway.Inter‐rater reliability for placed ROIs among experts was highest in VIBE images (lower confidence interval 0.84 to 0.97, mean 0.91) and lower in both ss‐EPI (0.61 to 0.95, mean 0.79) and rs‐EPI (0.59 to 0.86, mean 0.70).Tractography success rate based on streamline selection performance was highest in VIBE‐drawn ROIs registered (6‐DOF) onto rs‐EPI FOD (70.0% over 5%‐threshold, capped to failed ratio 39/16) followed by both 12‐DOF‐registered (67.5%; 41/16) and nonregistered VIBE (67.5%; 40/23). On ss‐EPI FOD, VIBE‐ROI‐datasets obtained fewer streamlines overall with each at 55.0% above 5%‐threshold and with lower capped to failed ratio (6‐DOF: 35/36; 12‐DOF: 34/34, nonregistered 33/36).The combination of VIBE‐placed ROIs (highest inter‐rater reliability) with 6‐DOF registration onto rs‐EPI targets (best streamline selection performance) is most suitable for white matter template generation required in group studies.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3