Is ultraviolet light disinfection fit to be the future standard for the disinfection of flexible endoscopes without a working channel?

Author:

Halmans Yana1ORCID,Wellenstein David J.1ORCID,Romijn Michael1,Cremers Suzan2,Smit Jannie J.3,Hopman Joost4,Takes Robert P.1,van den Broek Guido B.1

Affiliation:

1. Department of Otorhinolaryngology and Head and Neck Surgery Radboud University, Medical Center Nijmegen Nijmegen The Netherlands

2. Department of Hygiene and Infection Prevention Radboud University, Medical Center Nijmegen Nijmegen The Netherlands

3. Department of Pharmacy Radboud University, Medical Center Nijmegen Nijmegen The Netherlands

4. Department of Medical Microbiology Radboud University, Medical Center Nijmegen Nijmegen The Netherlands

Abstract

AbstractObjectiveTo investigate colony‐forming unit (CFU) reduction on contaminated flexible endoscopes (FEs) without a working channel after UV‐C light disinfection, compared to the current disinfection method with the endoscope washer disinfector (EWD).Design, setting and participantsAfter pharyngolaryngoscopy, a manual pre‐cleaning with tap water was performed. A culture was then collected by rolling the distal 8–10 cm of the FE over an Agar plate. The FE was disinfected using the D60 (60‐s disinfection process with UV‐C light) or the EWD (gold standard reprocessing process with water and chemicals). Another culture was then taken. After incubation, a CFU count was performed.ResultsA total of 200 FEs without a working channel were divided equally between the two disinfection groups. After clinical use and manual pre‐cleaning, 84 of the 100 (84.0%) (UV‐C light group) and 79 of the 100 (79.0%) (EWD) FEs were contaminated with at least 1 CFU. FEs that showed no contamination after use were excluded from further analysis. After disinfection with UV‐C light, 72 (85.7%) FEs showed no contamination (i.e., 0 CFUs) versus 66 (83.5%) FEs after reprocessing with the EWD.ConclusionThere is no difference in CFUs reduction on contaminated FEs without a working channel between UV‐C light disinfection and the current gold standard, the EWD.

Publisher

Wiley

Subject

Otorhinolaryngology

Reference25 articles.

1. Infectious diseases linked to cross-contamination of flexible endoscopes

2. Endoscopy-related infection: relic of the past?

3. Healthcare Infection Control Practices Advisory Committee.Essential elements of a reprocessing program for flexible endoscopes–The recommendations of the Healthcare Infection Control Practices Advisory Committee (HICPAC) 2016.https://www.cdc.gov/hicpac/pdf/flexible-endoscope-reprocessing.pdf.

4. SFEReD.Kwaliteitshandboek flexibele endoscopen 2019.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3