FLAER as a standalone reagent for paroxysmal nocturnal hemoglobinuria: Do we need to reconsider the guidelines for testing?

Author:

Sharma Praveen1ORCID,Bose Parveen1,Mallik Nabhajit1ORCID,Gupta Dikshat Gopal2ORCID,Rachagiri Suneel1ORCID,Kumar Arun1,Kaur Jasbir1,Malhotra Pankaj3,Varma Neelam1ORCID,Sachdeva Man Updesh Singh1

Affiliation:

1. Department of Hematology Post Graduate Institute of Medical Education and Research Chandigarh India

2. Department of Urology, The Robert H. Lurie Comprehensive Cancer Center Northwestern University Feinberg School of Medicine Chicago Illinois USA

3. Department of Clinical Hematology & Medical Oncology Post Graduate Institute of Medical Education and Research Chandigarh India

Abstract

AbstractIntroductionFlow cytometry‐based paroxysmal nocturnal hemoglobinuria (PNH) testing involves utilization of monoclonal antibodies against GPI‐linked proteins and FLAER. The ability of FLAER to bind to a wide variety of GPI‐linked structures and to be utilized across different leukocyte subsets is remarkable. We hypothesize that FLAER as a standalone reagent may be equally effective for detecting PNH clones. The present study intends to compare the results of a FLAER alone‐based strategy to the recommended FLAER+GPI‐linked protein‐based approach for applicability in clinical settings.MethodsEDTA‐anticoagulated blood samples from patients for PNH workup were tested for PNH by multiparametric flow cytometry. A conventional panel comprising gating markers (CD45 for WBC, CD15 for granulocytes, and CD64 for monocytes) and a combination of FLAER and GPI‐linked markers, such as CD24 and CD14, henceforth referred to as the “routine panel,” was employed. Second, a “FLAER‐only panel” comprising the gating markers and FLAER alone (excluding the GPI‐linked markers CD24 and CD14) was set up. The samples were processed using the lyse‐wash‐stain‐wash technique, and events were acquired on BC Navios Ex flow cytometer (Beckman Coulter, Inc., USA) and analyzed on Kaluza Software 2.1. The presence of a PNH clone was reported at a value of ≥0.01%.ResultsA total of 209 patients were tested. Both panels found a PNH clone in 20.1% of patients (n = 42/209) with a 100% concordance rate. The PNH clone range for granulocytes was 0.01%–89.68%, and for monocyte was 0.04%–96.09% in the routine panel. The range in the FLAER‐only panel for granulocytes was 0.01%–89.61%, and for monocytes, it was 0.01%–96.05%. Pearson correlation statistics revealed a significant correlation between the size of the PNH clone of granulocytes and monocytes among the two panels tested (granulocytes r = 0.9999, p < 0.0001, 95% CI = 0.9999 to 1.000; monocytes r = 0.9974, p < 0.0001, 95% CI = 0.9966–0.9980).ConclusionBased on our results, FLAER as a standalone marker is specific and sensitive for identifying PNH clones in granulocytes and monocytes, even for high‐sensitivity PNH assay. The proposed “FLAER‐only panel” panel is efficient and cost‐effective for highly sensitive PNH testing in two different cell lineages, especially in resource‐limited clinical settings.

Publisher

Wiley

Subject

Biochemistry (medical),Clinical Biochemistry,Hematology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3