Evaluation and patient experience of wireless noninvasive fetal heart rate monitoring devices

Author:

Eenkhoorn Chantal1ORCID,Goos Tom G.23ORCID,Dankelman Jenny3,Franx Arie1,Eggink Alex J.1

Affiliation:

1. Department of Obstetrics and Gynecology, Erasmus MC University Medical Center Rotterdam The Netherlands

2. Department of Neonatal and Pediatric Intensive Care, Erasmus MC University Medical Center Rotterdam The Netherlands

3. Department of Biomechanical Engineering Delft University of Technology Delft The Netherlands

Abstract

AbstractIntroductionIn clinical practice, fetal heart rate monitoring is performed intermittently using Doppler ultrasound, typically for 30 minutes. In case of a non‐reassuring heart rate pattern, monitoring is usually prolonged. Noninvasive fetal electrocardiography may be more suitable for prolonged monitoring due to improved patient comfort and signal quality. This study evaluates the performance and patient experience of four noninvasive electrocardiography devices to assess candidate devices for prolonged noninvasive fetal heart rate monitoring.Material and methodsNon‐critically sick women with a singleton pregnancy from 24 weeks of gestation were eligible for inclusion. Fetal heart rate monitoring was performed during standard care with a Doppler ultrasound device (Philips Avalon‐FM30) alone or with this Doppler ultrasound device simultaneously with one of four noninvasive electrocardiography devices (Nemo Fetal Monitoring System, Philips Avalon‐Beltless, Demcon Dipha‐16 and Dräger Infinity‐M300). Performance was evaluated by: success rate, positive percent agreement, bias, 95% limits of agreement, regression line, root mean square error and visual agreement using FIGO guidelines. Patient experience was captured using a self‐made questionnaire.ResultsA total of 10 women were included per device. For fetal heart rate, Nemo performed best (success rate: 99.4%, positive percent agreement: 94.2%, root mean square error 5.1 BPM, bias: 0.5 BPM, 95% limits of agreement: −9.7 – 10.7 BPM, regression line: y = −0.1x + 11.1) and the cardiotocography tracings obtained simultaneously by Nemo and Avalon‐FM30 received the same FIGO classification. Comparable results were found with the Avalon‐Beltless from 36 weeks of gestation, whereas the Dipha‐16 and Infinity‐M300 performed significantly worse. The Avalon‐Beltless, Nemo and Infinity‐M300 closely matched the performance of the Avalon‐FM30 for maternal heart rate, whereas the performance of the Dipha‐16 deviated more. Patient experience scores were higher for the noninvasive electrocardiography devices.ConclusionsBoth Nemo and Avalon‐Beltless are suitable devices for (prolonged) noninvasive fetal heart rate monitoring, taking their intended use into account. But outside its intended use limit of 36 weeks’ gestation, the Avalon‐Beltless performs less well, comparable to the Dipha‐16 and Infinity‐M300, making them currently unsuitable for (prolonged) noninvasive fetal heart rate monitoring. Noninvasive electrocardiography devices appear to be preferred due to greater comfort and mobility.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3