In‐vivo repeatability of three intra‐oral spectrophotometers

Author:

Hampé‐Kautz Vincent1,Roman Tatiana123ORCID,Schwob Thibault1,Cournault Bérangère12,Etienne Olivier123ORCID

Affiliation:

1. Robert Frank Dental Faculty University of Strasbourg Strasbourg France

2. INSERM U1121 Strasbourg France

3. Icube UMR7357 Strasbourg France

Abstract

AbstractObjectiveThe objective was to assess the repeatability of three spectrophotometers, based on the CIELCh factors and shadeguide reference measurements.Materials and MethodsColor analysis was performed using three devices: Rayplicker, Easyshade 4, and Easyshade V. Five repeated measures were performed by the same operator, on the right central maxillary incisor of 30 patients. The CIELCh factors were retrieved and the intra‐class correlation was calculated. The Vita Classical and Vita 3D Master shadeguides were used to evaluate the respective Fleiss' Kappa factors.ResultsRayplicker and Easyshade V demonstrated strong intra‐class correlation based on the CIELCh factors: 0.98, 0.99, and 0.91 for Rayplicker, and 0.95, 0.99, and 0.93 for Easyshade V, for the L*, C*, and h* parameters, respectively. Regarding the repeatability of the shadeguide data, while Easyshade 4 had the best repeatability when using the Vita Classical as a reference, Rayplicker and Easyshade V showed better repeatability when using the Vita 3D Master.ConclusionThese findings suggest that both Rayplicker and Easyshade V are reliable devices for measuring CIELCh parameters. In terms of shadeguide references, the reliability of spectrophotometers is generally lower compared to the CIELCh measurements.Clinical SignificanceGiven their good repeatability, both the Rayplicker and the Easyshade V spectrophotometers are reliable tools for prosthetic dental practices.

Publisher

Wiley

Reference34 articles.

1. Fixed prosthodontic patient satisfaction survey;Carek A;Psychiatr Danub,2021

2. A systematic review of visual and instrumental measurements for tooth shade matching;Chen H;Quintessence Int Berl Ger 1985,2012

3. Influence of light source, polarization, education, and training on shade matching quality

4. Dental Color Standards: Shade Tab Arrangement

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Optimizing Immunosuppression in Glomerular Diseases;Nature Cell and Science;2024-03-30

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3