In‐vivo repeatability of three intra‐oral spectrophotometers

Author:

Hampé‐Kautz Vincent1,Roman Tatiana123ORCID,Schwob Thibault1,Cournault Bérangère12,Etienne Olivier123ORCID

Affiliation:

1. Robert Frank Dental Faculty University of Strasbourg Strasbourg France

2. INSERM U1121 Strasbourg France

3. Icube UMR7357 Strasbourg France

Abstract

AbstractObjectiveThe objective was to assess the repeatability of three spectrophotometers, based on the CIELCh factors and shadeguide reference measurements.Materials and MethodsColor analysis was performed using three devices: Rayplicker, Easyshade 4, and Easyshade V. Five repeated measures were performed by the same operator, on the right central maxillary incisor of 30 patients. The CIELCh factors were retrieved and the intra‐class correlation was calculated. The Vita Classical and Vita 3D Master shadeguides were used to evaluate the respective Fleiss' Kappa factors.ResultsRayplicker and Easyshade V demonstrated strong intra‐class correlation based on the CIELCh factors: 0.98, 0.99, and 0.91 for Rayplicker, and 0.95, 0.99, and 0.93 for Easyshade V, for the L*, C*, and h* parameters, respectively. Regarding the repeatability of the shadeguide data, while Easyshade 4 had the best repeatability when using the Vita Classical as a reference, Rayplicker and Easyshade V showed better repeatability when using the Vita 3D Master.ConclusionThese findings suggest that both Rayplicker and Easyshade V are reliable devices for measuring CIELCh parameters. In terms of shadeguide references, the reliability of spectrophotometers is generally lower compared to the CIELCh measurements.Clinical SignificanceGiven their good repeatability, both the Rayplicker and the Easyshade V spectrophotometers are reliable tools for prosthetic dental practices.

Publisher

Wiley

Subject

General Dentistry

Reference34 articles.

1. Fixed prosthodontic patient satisfaction survey;Carek A;Psychiatr Danub,2021

2. A systematic review of visual and instrumental measurements for tooth shade matching;Chen H;Quintessence Int Berl Ger 1985,2012

3. Influence of light source, polarization, education, and training on shade matching quality

4. Dental Color Standards: Shade Tab Arrangement