In vitro comparison of one‐step, two‐step, and three‐step polishing systems on the surface roughness and gloss of different resin composites

Author:

Lippert Vinícius Funghetto1,Bresciani Eduardo2ORCID,Mota Eduardo Gonçalves1,Bittencourt Hélio Radke3,Kramer Paulo Floriani1,Spohr Ana Maria1ORCID

Affiliation:

1. Department of Restorative Dentistry, School of Dentistry Pontifical Catholic University of Rio Grande do Sul Porto Alegre Brazil

2. Department of Restorative Dentistry, School of Dentistry São Paulo State University São José dos Campos Brazil

3. Department of Statistics, Polytechnic School Pontifical Catholic University of Rio Grande do Sul Porto Alegre Brazil

Abstract

AbstractObjectivesThis laboratory study evaluated the effect of three polishing systems on the surface roughness and gloss of resin composites.Materials and MethodsThirty specimens (6 mm Ø × 8 mm) were fabricated from each of three resin composites: Z 350 XT (nanofill), Harmonize (nanohybrid), and Estelite Omega (supranonofill). All specimens were photopolymerized using a multi‐peak LED curing unit (VALO—Standard mode), having a exitance irradiance of approximately 1000 mW/cm2 against a polyester strip (PS). 2 mm was then removed from the irradiated end (finished) using #320 abrasive paper (F). Specimens were then randomly polished (P) using a one‐step (1S) (OneGloss), two‐step (2S) (EVE Diacomp Twist Basic CA), or 3‐step (3S) (Astropol P) system (n = 10). For PS, F, and P groups, surface roughness (Ra) was measured using a surface roughness tester, and surface gloss was measured with a glossmeter. For each specimen, the percent recovery to the PS value (%R) of surface roughness and surface gloss were calculated. Data were analyzed using two–way ANOVA, followed by Tukey's test. Surface roughness and gloss values were submitted to Pearson's correlation test (α = 0.05). All statistical testing was performed using a pre‐set alpha of 0.05.ResultsThe interaction term [resin composite × polishing system] was significant for both surface roughness (p = 0.001) and gloss (p = 0.0001). For all resin composites, the 2S and 3S systems provided a higher %R of surface roughness and gloss compared to those of the 1S system. There was a negative correlation between surface roughness and gloss, but only a few combinations showed strong correlations.ConclusionsThe 2S and 3S polishing systems provided surfaces having greater smoothness and gloss compared to the 1S system. The ability to recover surface roughness and gloss was dependent on type of resin composite filler classification.Clinical SignificanceThe 3S and 2S polishing systems were more effective in achieving PS values than was the 1S system for all tested resin composites. However, individual polishing systems performed differently depending on type of resin composite.

Funder

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Publisher

Wiley

Subject

General Dentistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3