Computer‐assisted bone augmentation, implant planning and placement: An in vitro investigation

Author:

Unger S.1ORCID,Benic G. I.2ORCID,Ender A.3,Pasic P.1,Hämmerle C. H. F.2ORCID,Stadlinger B.1ORCID

Affiliation:

1. Clinic of Cranio‐Maxillofacial and Oral Surgery, Center of Dental Medicine University of Zurich Zürich Switzerland

2. Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine University of Zurich Zürich Switzerland

3. Clinic for Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine University of Zurich Zürich Switzerland

Abstract

AbstractAimTo assess in vitro the workflow for alveolar ridge augmentation with customised 3D printed block grafts and simultaneous computer‐assisted implant planning and placement.MethodsTwenty resin mandible models with an edentulous area and horizontal ridge defect in the region 34–36 were scanned with cone beam computed tomography (CBCT). A block graft for horizontal ridge augmentation in the region 34–36 and an implant in the position 35 were digitally planned. Twenty block grafts were 3D printed out of resin and one template for guided implant placement were stereolithographically produced. The resin block grafts were positioned onto the ridge defects and stabilised with two fixation screws each. Subsequently, one implant was inserted in the position 35 through the corresponding template for guided implant placement. Optical scans of the study models together with the fixated block graft were performed prior to and after implant placement. The scans taken after block grafting were superimposed with the virtual block grafting plan through a best‐fit algorithm, and the linear deviation between the planned and the achieved block positions was calculated. The precision of the block fixation was obtained by superimposing the 20 scans taken after grafting and calculating the deviation between the corresponding resin blocks. The superimposition between the scans taken after and prior to implant placement was performed to measure a possible displacement in the block position induced by guided implant placement. The (98–2%)/2 percentile value was determined as a parameter for surface deviation.ResultsThe mean deviation in the position of the block graft compared to the virtual plan amounted to 0.79 ± 0.13 mm. The mean deviation between the positions of the 20 block grafts measured 0.47 ± 0.2 mm, indicating a clinically acceptable precision. Guided implant placement induced a mean shift of 0.16 ± 0.06 mm in the position of the block graft.ConclusionsWithin the limitations of this in vitro study, it can be concluded that customised block grafts fabricated through CBCT, computer‐assisted design and 3D printing allow alveolar ridge augmentation with clinically acceptable predictability and reproducibility. Computer‐assisted implant planning and placement can be performed simultaneously with computer‐assisted block grafting leading to clinically non‐relevant dislocation of block grafts.

Publisher

Wiley

Subject

Oral Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Clinical Applications of 3D-Printed Polymers in Dentistry: A Scoping Review;International Journal of Prosthodontics;2024-02-21

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370