Accuracy of positive airway pressure titration through telemonitoring of auto‐adjusting positive airway pressure device connected to a pulse oximetry in patients with obstructive sleep apnea

Author:

Foresi Antonio1ORCID,Vitale Tommaso1,Prestigiacomo Rosaria1,Ranieri Piera2,Bosi Marcello3

Affiliation:

1. Lung Function and Sleep Unit ASST Nord‐Milano, Sesto San Giovanni Hospital Milan Italy

2. Department of Medicine and Rehabilitation Istituto Clinico Sant'Anna Brescia Italy

3. Sleep Unit Villa Igea, Ospedali Privati Forlì Forlì Italy

Abstract

AbstractPurposeIn COVID‐19 era, all forms of access of patients to the sleep units should be reduced as much as possible when implementing telemedicine. In the field of obstructive sleep apnea (OSA) therapy with positive airway pressure (PAP) devices, telemedicine includes the use of built‐in software (BIS) and storage of PAPs and remote‐controlled data (BISrc data) that are processed and transmitted daily to sleep units.We compared two methods of evaluating the final residual severity of OSA patients in home PAP titration: BISrc data versus nocturnal portable multichannel monitoring (PM) data in PAP (reference method) and to verify whether the efficacy PAP therapy guided by BISrc data was clinically adequate.MethodsWe conducted a real‐life prospective study in newly diagnosed patients with OSA. Patients used an auto‐adjusting positive airway pressure (AirSense 10 ResMed) with a pulse oximeter that allows daily transfer of BISrc data (apnea hypopnea index [AHI] and SaO2) and remote changes in ventilator setting. Once the PAP titration was completed, the pressure value or ranges were kept constant for 3 days and home PM was repeated.ResultsThere were 41 patients with moderate to severe OSA who completed the study. When considering AHI only, the diagnostic accuracy of BISrc on the third day was equal to 97.5%; when considering AHI > 10/h, ODI > 10/h, and SaO2 < 90%, the diagnostic accuracy slightly decreased to 90.2%.ConclusionIn clinical practice, the two measurement methods are equivalent. The use of BISrc data for home titration would reduce the access to sleep units. We urge that widespread use of BISrc be promoted in the current practice of management of OSA.

Publisher

Wiley

Subject

Genetics (clinical),Pulmonary and Respiratory Medicine,Immunology and Allergy

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献