The feasibility of ultrasonography for the measurement of periodontal and peri‐implant phenotype: A systematic review and meta‐analysis

Author:

Fan Shengchi12ORCID,Sáenz‐Ravello Gustavo3ORCID,Al‐Nawas Bilal1ORCID,Schiegnitz Eik1,Diaz Leonardo4ORCID,Sagheb Keyvan1

Affiliation:

1. Department of Oral and Maxillofacial Surgery – Plastic Operations University Medical Center Mainz Mainz Germany

2. School of Medicine; National Clinical Research Center for Oral Disease, Shanghai Key Laboratory of Stomatology & Shanghai Research Institute of Stomatology Second Dental Clinic, Ninth People's Hospital, College of Stomatology, Shanghai Jiao Tong University Shanghai China

3. Center for Epidemiology and Surveillance of Oral Diseases (CESOD), Faculty of Dentistry Universidad de Chile Santiago Chile

4. Postgraduate School, Faculty of Dentistry Universidad de Chile Santiago Chile

Abstract

AbstractBackgroundScreening ultrasonography was proposed for monitoring periodontal soft tissues in the early 1960s, owing to its nonionizing, real‐time, and cost‐effective properties. Studies have provided convincing preliminary evidence for the use of ultrasound (US) in implant dentistry.PurposeTo assess the feasibility of ultrasonography (US) for measuring the buccal thickness of periodontal and peri‐implant tissues. The secondary objective was to evaluate the reliability of US measurements compared to classic techniques, such as CBCT and directly measurements.Materials and MethodsAn electronic literature search was conducted by three independent reviewers through February 2023. The inclusion criteria were articles investigating at least five patients/cadavers with US measurements in periodontal or peri‐implant buccal tissues. Compliance with methodological reporting standards and risk of bias was assessed using EULAR and QUADAS‐C tools, respectively. Random‐effects meta‐analysis was conducted, using Bland–Altman analysis. Certainty of the evidence was assessed using GRADE.ResultsThe final selection included 12 studies examining 458 patients and 13 cadavers, with a total of 226 implants, 1958 teeth and 60 edentulous sites. The body of evidence was assessed as partially compliant with methodological reporting standards for US studies and had an unclear to high risk of bias. Meta‐analysis of five comparative studies showed no evidence of clinically significant bias between US and direct measurements (very low certainty), and between US and CBCT (very low certainty) for soft‐tissue thickness. Likewise, for bone thickness, there is no evidence of clinically significant bias between US and CBCT (low certainty).ConclusionsCompared to the CBCT and direct measurements, ultrasonography might be a reliable approach for monitoring on periodontal and peri‐implant phenotype. However, there is uncertainty about estimates of the actual effect, so further standardized and larger sample size of clinical research is needed.

Publisher

Wiley

Subject

General Dentistry,Oral Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3