Automatic tablet‐based monoplane quantification of stroke volume and left ventricular ejection fraction: A comparative assessment against computer‐based biplane and monoplane tools

Author:

de Raat Frederique M.12ORCID,Bingley Peter2ORCID,Bouwmeester Sjoerd3ORCID,Felix Suzanne E. A.3ORCID,Montenij Leon J.12ORCID,Bouwman Arthur R.12ORCID

Affiliation:

1. Department of Anesthesiology Catharina Hospital Eindhoven The Netherlands

2. Department of Electrical Engineering Technical University of Eindhoven Eindhoven The Netherlands

3. Department of Cardiology Catharina Hospital Eindhoven The Netherlands

Abstract

AbstractBackgroundPoint‐of‐care cardiovascular left ventricle ejection fraction (LVEF) quantification is established, but automatic tablet‐based stroke volume (SV) quantification with handheld ultrasound (HAND) devices is unexplored. We evaluated a tablet‐based monoplane LVEF and LV volume quantification tool (AutoEF) against a computer‐based tool (Tomtec) for LVEF and SV quantification.MethodsPatients underwent HAND scans, and LVEF and SV were quantified using AutoEF and computer‐based software that utilized either apical four‐chamber views (Auto Strain‐monoplane [AS‐mono]) or both apical four‐chamber and apical two‐chamber views (Auto Strain‐biplane [AS‐bi]). Correlation and Bland–Altman analysis were used to compare AutoEF with AS‐mono and AS‐bi.ResultsOut of 43 participants, eight were excluded. AutoEF showed a correlation of .83 [.69:.91] with AS‐mono for LVEF and .68 [.44:.82] for SV. The correlation with AS‐bi was .79 [.62:.89] for LVEF and .66 [.42:.81] for SV. The bias between AutoEF and AS‐mono was 4.88% [3.15:6.61] for LVEF and 17.46 mL [12.99:21.92] for SV. The limits of agreement (LOA) were [−5.50:15.26]% for LVEF and [−8.02:42.94] mL for SV. The bias between AutoEF and AS‐bi was 6.63% [5.31:7.94] for LVEF and 20.62 mL [16.18:25.05] for SV, with LOA of [−1.20:14.47]% for LVEF and [−4.71:45.94] mL for SV.ConclusionLVEF quantification with AutoEF software was accurate and reliable, but SV quantification showed limitations, indicating non‐interchangeability with neither AS‐mono nor AS‐bi. Further refinement of AutoEF is needed for reliable SV quantification at the point of care.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3