The Optimal Variation Range of Posterior Condylar Offset Associated with Positive Clinical Outcomes of Primary Total Knee Arthroplasty: A Retrospective Analysis

Author:

Zhong Yanlin1,Deng Zengfa1,Gu Cheng1ORCID,Li Ming1,Kang Yan1,Liao Weiming1,Zhang Zhiqi1ORCID

Affiliation:

1. Department of Joint Surgery the First Affiliated Hospital of Sun Yat‐sen University Guangzhou China

Abstract

ObjectivePosterior condylar offset (PCO) and anterior condylar offset (ACO) exert an influence on the sagittal alignment in total knee arthroplasty (TKA). However, there is no common consensus that the variation range of posterior condylar offset (PCO) is associated with patient‐reported outcome measures (PROMs) and the optimum variation range of PCO. This study aims to investigate the correlation between PCO and the PROMs of primary TKA for osteoarthritis (OA) and find out the optimal variation range of the PCO.MethodsIn this study, we performed a radiographic analysis of 106 patients (112 knees) with primary TKA. Patients were divided into two cohorts (A and B) according to the Western Ontario and McMaster Universities Osteoarthritis index (WOMAC). Correlations between the sagittal parameter and WOMAC were investigated using univariate and multivariate analysis. The receiver operating characteristic (ROC) curve was used to establish the cut‐off value for the optimal variation range. We then further investigated how different variation range affects the WOMAC subscale score and forgotten‐joint‐score‐12 (FJS‐12).ResultsUnivariate analysis revealed a correlation between the variation range of PCO (p < 0.01), ACO (p < 0.01) and PROMs. Multivariate analysis showed that only PCO was associated with PROMs. In the ROC graph, the cut‐off value of the variation range of PCO is 2.85 mm (AUC = 0.66, Youden index = 0.26). The WOMAC functional ability score of the group outside the PCO variation range of 2.85 mm significantly increased compared to the group within the range.ConclusionIn this study, PCO variation was significantly associated with clinical outcomes in TKA and the optimal PCO variation range was within 2.85 mm. Maintaining the PCO variation within 2.85 mm could enhance functional recovery and patient satisfaction.

Funder

Sun Yat-sen University

National Natural Science Foundation of China

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3