The effect of thermomechanical aging on the retention of a conometric system in a chewing simulator

Author:

Al‐Chalabi Zainab S.1,Tuna Süleyman H.2ORCID

Affiliation:

1. Department of Prosthodontics Faculty of Dentistry Suleyman Demirel University Isparta Turkey

2. Department of Prosthodontics Faculty of Dentistry Dokuz Eylul University Izmir Turkey

Abstract

AbstractPurposeTo evaluate the retention force of a novel conometric system after thermomechanical aging. In addition, the conometric system's retention force was compared with that of the cemented implant‐retained crowns.Materials and methodsTwo systems to retain implant crowns were tested in this study: a conometric system and a cement‐retained system. Forty‐eight zirconia crowns were fabricated using computer‐aided design and computer‐aided manufacturing technology. Twenty‐four zirconia crowns were cemented onto conometric caps with resin‐modified glass ionomer cement, which were then connected with abutments. These specimens were divided into three groups, and each group was subjected to the pull‐out test. A‐control group: 12 specimens directly subjected to pull‐out test; A‐aged group: 12 specimens subjected to thermomechanical aging followed by pull‐out test; A‐repeat group: After the pull‐out, the specimens in the aging group (A‐aged) were reconnected, and the pull‐out test was repeated once more. The remaining 24 zirconia crowns were cemented on standard abutments with zinc phosphate cement, and two groups were formed. C‐control group: 12 specimens directly subjected to the pull‐out test; C‐aged group: 12 specimens subjected to thermomechanical aging followed by pull‐out. Scanning electron microscope (SEM) was used to evaluate the surfaces of caps and abutments. To analyze the data, repeated measures, one‐way ANOVA, and Bonferroni tests were used (p < 0.05).ResultsThe mean retention force value of the A‐control group was 148.22 ± 16.37 N. The highest mean retention force value was measured in the A‐aged group (204.93 ± 51.67 N), and the lowest mean retention force value was seen in the A‐repeated group (77.02 ± 21.48 N). Thermomechanical aging had a significant influence (p < 0.05) on both systems. No significant differences in retention force were found between the thermomechanical aged groups of both systems (p > 0.05). SEM analysis revealed that aging had an impact on the surface of the conometric system's caps and abutments.ConclusionsThe retention force of the conometric system increased significantly following thermomechanical aging. No crown separation occurred during the thermomechanical aging of the conometric system. There was no significant difference in the retention of the conometric and cemented systems after thermomechanical aging.

Publisher

Wiley

Subject

General Dentistry

Reference39 articles.

1. Prosthetic complications in fixed endosseous implant-borne reconstructions after an observations period of at least 40 months

2. To what extent does the longevity of fixed dental prostheses depend on the function of the cement? Working Group 4 materials: cementation;Edelhoff D;Clin Oral Implants Res,2008

3. Clinical application of a shape memory implant abutment system

4. Clinical effectiveness of implant‐supported single‐tooth replacement: the Toronto Study;Avivi‐Arber L;Int J Oral Maxillofac Implants,1996

5. Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3