Affiliation:
1. Private Practice Kaunas Lithuania
2. Institute of Biomedical Sciences, Department of Physiology Biochemistry Microbiology and Laboratory Medicine, Faculty of Medicine Vilnius University Vilnius Lithuania
3. Institute of Odontology Vilnius University Vilnius Lithuania
4. Department of Dental and Oral Pathology Lithuanian University of Health Science Kaunas Lithuania
Abstract
AbstractPurposeThis is a randomized clinical trial to compare the clinical and immunological performance of ultrasmooth versus conventionally‐smooth zirconia abutments placed subgingivally after a period of 1 year.Materials and methodsSixty‐two bone level platform‐switched implants (NobelParallel CC) were placed epicrestally in the mandibular molar or premolar region in 62 patients. After osseointegration, implants were restored with auto polymerizing acrylic resin crowns and subsequently randomly allocated to two groups according to the type of screw‐retained zirconia crown prescribed. The control group received custom zirconia restoration with the subgingival zirconia part conventionally polished, whereas the test group implants were restored with ultra‐polished zirconia abutments. Periodontal parameters (PD, PI, and BOP) and marginal bone level changes (MBLC) were recorded for each implant 2 months after insertion (T0), 1 month after final delivery of the crown (T2), and at the 1‐year follow‐up (T3). Immunological mediators from gingival crevicular fluid (IL‐1α, IL‐1ra, and TNF‐α) were inspected at 1 month after provisional (T1) and accordingly at T2 and T3. Data was analyzed statistically, and significance level was set to α = 0.05.ResultsAfter 1 year, there were no significant changes in PD control—2.18 ± 0.89 mm and test—2.5 ± 0.72 mm (p = 0.073). PD between T2 and T3 dropped significantly in the test group (p = 0.037) and remained stable in the control group. PI was not different in both groups at T0 (p = 0.518) and T2 (p = 0.817). At T3, the test group (0.9 ± 1.01) had a significantly lower PI than the control group (1.55 ± 1.23) (p = 0.035). There was no difference in BOP positive cases between groups after 1 year (control—61.3%, test—51.7%, and p = 0.455). The amount of IL‐1ra decreased significantly in the test group (41.75 ± 57.58) (p = 0.001) but not in the control group (59.59 ± 70.43) (p = 0.177). MBLC for the control and test groups after 1 year were 0.68 ± 0.7 and 0.94 ± 0.65 mm (p = 0.061).ConclusionsPD dynamics, PI, BOP, and IL‐1ra revealed better outcomes around ultra‐polished zirconia abutments than around conventionally polished zirconia abutments.
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献