Clinical and immunological evaluation of peri‐implant tissues around ultra‐polished and conventionally‐polished zirconia abutments. A 1‐year follow‐up randomized clinical trial

Author:

Valantijiene Valda1,Mazeikiene Asta2,Alkimavicius Jonas1,Linkeviciene Laura3,Alkimaviciene Evelina4,Linkevicius Tomas3ORCID

Affiliation:

1. Private Practice Kaunas Lithuania

2. Institute of Biomedical Sciences, Department of Physiology Biochemistry Microbiology and Laboratory Medicine, Faculty of Medicine Vilnius University Vilnius Lithuania

3. Institute of Odontology Vilnius University Vilnius Lithuania

4. Department of Dental and Oral Pathology Lithuanian University of Health Science Kaunas Lithuania

Abstract

AbstractPurposeThis is a randomized clinical trial to compare the clinical and immunological performance of ultrasmooth versus conventionally‐smooth zirconia abutments placed subgingivally after a period of 1 year.Materials and methodsSixty‐two bone level platform‐switched implants (NobelParallel CC) were placed epicrestally in the mandibular molar or premolar region in 62 patients. After osseointegration, implants were restored with auto polymerizing acrylic resin crowns and subsequently randomly allocated to two groups according to the type of screw‐retained zirconia crown prescribed. The control group received custom zirconia restoration with the subgingival zirconia part conventionally polished, whereas the test group implants were restored with ultra‐polished zirconia abutments. Periodontal parameters (PD, PI, and BOP) and marginal bone level changes (MBLC) were recorded for each implant 2 months after insertion (T0), 1 month after final delivery of the crown (T2), and at the 1‐year follow‐up (T3). Immunological mediators from gingival crevicular fluid (IL‐1α, IL‐1ra, and TNF‐α) were inspected at 1 month after provisional (T1) and accordingly at T2 and T3. Data was analyzed statistically, and significance level was set to α = 0.05.ResultsAfter 1 year, there were no significant changes in PD control—2.18 ± 0.89 mm and test—2.5 ± 0.72 mm (p = 0.073). PD between T2 and T3 dropped significantly in the test group (p = 0.037) and remained stable in the control group. PI was not different in both groups at T0 (p = 0.518) and T2 (p = 0.817). At T3, the test group (0.9 ± 1.01) had a significantly lower PI than the control group (1.55 ± 1.23) (p = 0.035). There was no difference in BOP positive cases between groups after 1 year (control—61.3%, test—51.7%, and p = 0.455). The amount of IL‐1ra decreased significantly in the test group (41.75 ± 57.58) (p = 0.001) but not in the control group (59.59 ± 70.43) (p = 0.177). MBLC for the control and test groups after 1 year were 0.68 ± 0.7 and 0.94 ± 0.65 mm (p = 0.061).ConclusionsPD dynamics, PI, BOP, and IL‐1ra revealed better outcomes around ultra‐polished zirconia abutments than around conventionally polished zirconia abutments.

Publisher

Wiley

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3