Effect of a new support design on the marginal and internal gap of additively manufactured interim crowns using direct light deposition technology

Author:

Khanlar Leila Nasiry1ORCID,Francis Claire1,Basir Barmak Abdul2,Rios Alma L. Salazar3,Ashtiani Reza Eftekhar4,Zandinejad Amirali15ORCID

Affiliation:

1. Department of Comprehensive Dentistry College of Dentistry, Texas A&M University Dallas Texas USA

2. Department of Comprehensive Dentistry EIOH Medical Center, University of Rochester Rochester New York USA

3. Department of Prosthodontics College of Dentistry, Texas A&M University Dallas Texas USA

4. Department of Prosthodontics, School of Dentistry Shahid Beheshti University of Medical Sciences Tehran Iran

5. Private Practice Arlington Texas USA

Abstract

AbstractPurposeTo investigate the design and location of supporting structures on the marginal and internal gap of interim restorations.Materials and methodsA mandibular right first molar resin tooth was prepared for a full coverage crown and scanned using a laboratory scanner (3Shape D900). The scanned data were converted into standard tessellation language (STL) format and an indirect prosthesis was designed using computer‐aided design (CAD) software (exocad DentalCAD). The STL file was used to fabricate a total of 60 crowns with a 3D printer (EnvisionTEC Vida HD). The crowns were printed using E‐Dent C&B MH resin and divided into 4 groups based on four different support structure designs, including supports on the occlusal (0° group), buccal and occlusal (45° group), buccal (90° group), and a new design consisting of horizontal bars placed on all surfaces and line angles (Bar) (n = 15). The silicone replica technique was used to determine the gap discrepancy. Fifty measurements were obtained for each specimen to examine the marginal and internal gaps by using a digital microscope (Olympus SZX16) at ×70 magnification. Additionally, the marginal discrepancy at different locations of the tested crowns, including buccal (B), lingual (L), mesial (M), and distal (D), as well as the maximum and minimum marginal gap intervals among groups, were analyzed. The collected data were analyzed using factorial ANOVA, followed by the Tukey HSD test for multiple comparisons (a = 0.05).ResultsThere was a significant difference in marginal and internal gaps among the groups (p < 0.001). The buccal placement supports (90° group) had the least marginal and internal discrepancies (p < 0.001). The new design group showed the highest marginal and internal gap. The marginal discrepancy in different locations of the tested crowns (B, L, M, D) was found to be significantly different among the groups (p < 0.001). The mesial margin of the Bar group had the largest marginal gap, whereas the buccal margin of the 90° group had the lowest marginal gap. The new design had a significantly smaller difference between the maximum and minimum marginal gap intervals than other groups (p < 0.001).ConclusionThe location and design of the supporting structures affected the marginal and internal gaps of an interim crown. The buccal placement of supporting bars (90° printing orientation) showed the smallest mean internal and marginal discrepancies.

Publisher

Wiley

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3