Comparing the accuracy of occlusal vertical dimension transfer in CAD–CAM dentures

Author:

Satin Sara R.1ORCID,Goodacre Brian J.2ORCID,Masri Radi1ORCID

Affiliation:

1. Department of Oral Sciences and Pain. Division of Prosthodontics University of Maryland Baltimore Maryland USA

2. Division of General Dentistry Loma Linda University Loma Linda California USA

Abstract

AbstractPurposeThere are different methods to transfer occlusal vertical dimension (OVD) when fabricating complete dentures, but it is not clear which method yields the most accurate transfer. This study investigated the accuracy of transferring the OVD of the maxillary/mandibular relationship when designing and fabricating digital dentures by evaluating two commonly used workflows: duplicate dentures (DDs) and occlusion rims (ORs).Materials and methodsMounted edentulous casts were used to simulate a completely edentulous patient. These casts were used in two workflows: (1) DD workflow where complete dentures were fabricated and relined (n = 15), and (2) OR where final impressions and ORs were constructed (n = 15). Relined dentures and ORs with fiduciary markers were then scanned and virtually articulated, then exported as STL files. A scan of the articulated casts (simulated patients) with fiduciary markers embedded was also exported as an STL file and used as a control. STL files for each workflow were superimposed over the control and analyzed in 3D inspection software (Geomagic Control X, 3D Systems, NC) for deviations (mm) at three different locations. Average 3D deviations were compared among the groups using a two‐way ANOVA (α—0.05).ResultsThe average deviation for OR was significantly larger than DD at all locations of measurement [F = 46.00, p < 0.0001]. The majority of the measurements (98.9%) had a positive deviation value, indicating increased OVD. The overall deviation for the OR group from the control was 0.72 ± 0.13 mm versus 0.45 ± 0.23 mm for the DD group. There was no difference in deviation between the points of measurement and no interaction between the location and method [F = 0.02, p < 0.98].ConclusionsThe DD workflow exhibited less deviation in the transfer of OVD than the OR workflow. However, the deviation was small and may not be clinically significant.

Publisher

Wiley

Subject

General Dentistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3