Abstract

ObjectiveDynamization of the external fixator, defined as gradually decreasing construct‐stability of the fixator, is widely accepted as a method for treatment during the late phase of the bone healing process. However, the dynamization is mostly based on the subjective experience of orthopaedists at present, without unified standards and a clear theoretical basis. The objective of the study is to investigate the influence of the dynamization operations on the tibial mechanical properties with a hexapod circular external fixator and standardize the dynamization process.MethodsA 3D‐printed tibial defects model with Young's modulus of 10.5 GPa and Poisson's ratio of 0.32 simulated the clinically fractured bone. A 10 × ∅ 45 mm silicone sample with Young's modulus of 2.7 MPa and Poisson's ratio of 0.32 simulated the callus in the fracture site. Furthermore, a hexapod circular external fixator whose struts were coded from #1 to #6 was fixed on the model with six half‐pins (5 mm diameter). Corresponding to the action of removing and loosening the struts, 17 dynamization operations are designed. For each construct after different dynamization operations, the mechanical environment changes in the fracture site were recorded by a triaxle forces sensor under gradually increasing external load from 0 to 500 N.ResultsThe results show that the bone axial load‐sharing ratio of each construct in the removal group was generally higher than that in the loosening group. The ratio increased from 92.51 ± 0.74% to 102.68 ± 0.27% with the number of operated struts rising from 2 to 6. Besides, the constructions with the same number of operated struts but with different strut codes such as constructions 3–5, had similar bone axial load‐sharing ratios. In addition, the proposed dynamization method of the hexapod circular external fixator can gradually increase the bone axial load‐sharing ratio from 90.73 ± 0.19% to 102.68 ± 0.27% and maintain the bone radial load‐sharing ratio below 8%.ConclusionThe laboratory study verified the effects of the type of operations and the number of operated struts on the bone axial load‐sharing ratio, as well as the slight influence of the choice of the strut code. Besides, a dynamization method of the hexapod circular external fixator was proposed to increase the bone axial load‐sharing ratio gradually.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3