Effect of polishing and denture cleansers on the surface roughness of new‐generation denture base materials and their color change after cleansing

Author:

Çakmak Gülce1ORCID,Hess Julia Anouk1,Dönmez Mustafa Borga12ORCID,Yılmaz Deniz3ORCID,Alhotan Abdulaziz4ORCID,Schimmel Martin15,Peutzfeldt Anne67,Yilmaz Burak168ORCID

Affiliation:

1. Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine University of Bern Bern Switzerland

2. Department of Prosthodontics, Faculty of Dentistry Istinye University Istanbul Turkey

3. Department of Prosthodontics, Faculty of Dentistry Alanya Alaaddin Keykubat University Antalya Turkey

4. Dental Health Department, College of Applied Medical Sciences King Saud University Riyadh Saudi Arabia

5. Division of Gerodontology and Removable Prosthodontics University Clinics of Dental Medicine, University of Geneva Geneva Switzerland

6. Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine University of Bern Bern Switzerland

7. Department of Odontology, Faculty of Health and Medical Sciences University of Copenhagen Copenhagen Denmark

8. Division of Restorative and Prosthetic Dentistry The Ohio State University College of Dentistry Columbus Ohio USA

Abstract

AbstractPurposeTo evaluate the effect of polishing and denture cleansers on the surface roughness (Ra) of new‐generation denture base materials that are additively, subtractively, and conventionally fabricated, while also assessing their color change after cleansing.Material and MethodsOne hundred and fifty disk‐shaped specimens (Ø10 × 2 mm) were prepared from five denture base materials (one subtractively manufactured nanographene‐reinforced prepolymerized polymethylmethacrylate (PMMA) (SM‐GC), one subtractively manufactured prepolymerized PMMA (SM‐PM), two additively manufactured denture base resins (AM‐DT and AM‐ND), and one heat‐polymerized PMMA (CV) (n = 30). The Ra of the specimens was measured before and after conventional laboratory polishing, while color coordinates were measured after polishing. Specimens were then divided into three subgroups based on the denture cleanser: distilled water, 1% sodium hypochlorite (NaOCl), and effervescent tablet (n = 10). The Ra and color coordinates were remeasured after nine cleansing cycles over a period of 20 days. The CIEDE2000 formula was used to calculate the color differences (ΔE00). Two‐way analysis of variance (ANOVA) was used to analyze the Ra values before (n = 30) and after (n = 10) cleansing, while repeated measures ANOVA was used to analyze the Ra of material‐time point pairs within each denture cleanser (n = 10). ΔE00 data after denture cleansing was also analyzed by using two‐way ANOVA (n = 10) (α = 0.05).ResultsBefore polishing, Ra varied significantly among the materials. SM‐GC and SM‐PM had the lowest and AM‐ND the highest Ra values (P < 0.001). Polishing significantly reduced Ra of all materials (P < 0.001), and after polishing, Ra differences among materials were nonsignificant (P ≥ 0.072). Regardless of the denture cleanser, the Ra of AM‐DT, AM‐ND, and CV was the highest before polishing when different time points were considered (P < 0.001). After cleansing, AM‐ND had the highest Ra of all the materials, regardless of the cleanser (P ≤ 0.017). AM‐DT had higher Ra than SM‐PM when distilled water (P = 0.040) and higher Ra than SM‐GC, SM‐PM, and CV when NaOCl was used (P < 0.001). The type of cleanser significantly influenced the Ra of AM‐DT, AM‐ND, and CV. For AM‐DT, NaOCl led to the highest Ra and the tablet led to the lowest Ra (P ≤ 0.042), while for AM‐ND, distilled water led to the lowest Ra (P ≤ 0.024). For CV, the tablet led to lower Ra than distilled water (P = 0.009). Color change varied among the materials. When distilled water was used, SM‐GC had higher ΔE00 than SM‐PM and AM‐DT (P ≤ 0.034). When NaOCl was used, AM‐ND had higher ΔE00 than SM‐GC, SM‐PM, and AM‐DT, while CV and SM‐GC had higher ΔE00 than SM‐PM and AM‐DT (P ≤ 0.039). Finally, when the tablet was used, AM‐ND and CV had the highest ΔE00, while AM‐DT had lower ΔE00 than SM‐GC (P ≤ 0.015).ConclusionsThe tested materials had unacceptable surface roughness (>0.2 μm) before polishing. Roughness decreased significantly after polishing (<0.2 μm). Denture cleansers did not significantly affect the surface roughness of the materials, and roughness remained clinically acceptable after cleansing (<0.2 μm). Considering previously reported color thresholds, AM‐ND and CV had unacceptable color change regardless of the denture cleanser, and the effervescent tablet led to perceptible, but acceptable color change for SM‐GC, SM‐PM, and AM‐DT.

Publisher

Wiley

Subject

General Dentistry

Reference33 articles.

1. CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes

2. Effect of simulated brushing and disinfection on the surface roughness and color stability of CAD-CAM denture base materials

3. Evaluation of flexural strength and surface properties of prepolymerized CAD/CAM PMMA‐based polymers used for digital 3D complete dentures;Arslan M;Int J Comput Dent.,2018

4. PMMA denture base material enhancement: a review of fiber, filler, and nanofiller addition

5. Improving PMMA resin using graphene oxide for a definitive prosthodontic rehabilitation – a clinical report;Azevedo L;J Clin Exp Dent.,2019

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3