Effect of implant angulation and patrice on the retention of overdenture attachment systems: An in vitro study

Author:

Frantz Kristen1ORCID,Funkenbusch Paul2,Feng Changyong3,Tsigarida Alexandra4,Chochlidakis Konstantinos1ORCID,Lo Russo Lucio5ORCID,Ercoli Carlo14ORCID

Affiliation:

1. Department of Prosthodontics Eastman Institute for Oral Health University of Rochester Rochester New York USA

2. Department of Mechanical Engineering University of Rochester Rochester New York USA

3. Department of Biostatistics and Computational Biology University of Rochester Rochester New York USA

4. Department of Periodontology Eastman Institute for Oral Health University of Rochester Rochester New York USA

5. Department of Clinical and Experimental Medicine University of Foggia Foggia Italy

Abstract

AbstractPurposeTo test the retention of two different overdenture attachment matrices and straight abutments when implants are placed at 0‐, 15‐, and 30‐degree diverging angulations as well as the retention of 15‐degree‐angled abutments to correct the overall angulation to 0‐degrees.Materials and MethodsMatching aluminum blocks were machined to incorporate two dental implants at 0‐degree, 15‐degree, and 30‐degree relative angulations and overdenture attachments to simulate a two‐implant overdenture. At 0‐degree, 15‐degree, and 30‐degree implant angulation, straight abutments were studied. At 30‐degree implant angulation, an additional group was compared utilizing 15‐degree angulated abutments that corrected the overall implant angulation to 0‐degrees. A custom‐designed testing apparatus that allowed automated insertion and removal of the simulated overdenture was designed, with three independent testing stations, each consisting of one simulated arch and one simulated overdenture base. The baseline and residual retention forces after 30,000 dislodging cycles of the simulated overdenture were measured. One‐way ANOVA was used to compare retention differences among different color patrices within the 0‐, 15‐, and 30‐degree implant angulation groups followed by Tukey's multiple comparison test. Two sample t‐tests were used to compare 0‐degree versus 15‐degree implant groups with straight abutments and 30‐degree implant groups with straight abutments versus 30‐degree implant groups with angulated abutments.ResultsRegardless of implant angulation or abutment correction, the change in retention exhibited by the Novaloc system after testing was not statistically significant for all patrice types (p > 0.05); however, the change in retention exhibited by the Locator system was statistically significant for the tested group (p = 0.0272). In both the Novaloc and Locator systems, the baseline and final retention values provided by the different patrices were significantly different except for the white and green Novaloc patrices in the 15‐degree divergent implant group which did not meet the specified level of significance (p = 0.0776).ConclusionWithin the limitations of this study, implant angulations upto 15 degrees do not affect differential change in retention of Novaloc patrices. There is no difference between Novaloc white inserts (light retention value) and green inserts (strong retention values) when implants diverge upto 15 degrees. When Novaloc straight abutments were placed on implants diverging by 30 degrees, blue extra‐strong retention inserts outperformed yellow medium retention inserts by maintaining a higher retention value after 30,000 cycles. When utilizing Novaloc 15‐degree angulated abutments that correct the overall implant angulation to zero degrees, the red light retentive patrice provides steady retention. Finally, the Locator‐green patrice system provides greater retention than the comparable Novaloc‐blue patrice combination; however, it also loses more retention after 30,000 cycles.

Publisher

Wiley

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3