Validation and clinical application of implantable loop recorders for diagnosis of atrial fibrillation in horses

Author:

Kjeldsen Sofie Troest1ORCID,Nissen Sarah D.1ORCID,Christensen Nina C.1,Haugaard Simon L.1ORCID,Schneider Mélodie J.1,Vinther Zenta1,Sattler Stefan M.23,Carstensen Helena1,Jøns Christian4,Hopster‐Iversen Charlotte1,Buhl Rikke1ORCID

Affiliation:

1. Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences University of Copenhagen Copenhagen Denmark

2. Department of Cardiology Herlev and Gentofte University Hospital Gentofte Denmark

3. Department of Biomedical Sciences, Faculty of Health and Medical Sciences University of Copenhagen Copenhagen Denmark

4. Department of Cardiology, The Heart Centre Copenhagen University Hospital, Rigshospitalet Copenhagen Denmark

Abstract

AbstractBackgroundParoxysmal atrial fibrillation (pAF) occurs sporadically and can impair athletic performance. Gold standard for diagnosis is surface electrocardiography (ECG), however, this requires AF to be sustained. Implantable loop recorders (ILRs) are routinely used for AF detection in human medicine. While ILR placement has been studied in horses, its AF detection performance is unknown.Objectives(I) Validation of ILRs for AF detection in horses. (II) Determining pAF incidence using ILRs and estimate the positive predictive value (PPV).Study design(I) Experimental study; (II) Longitudinal observational study.Methods(I) Implantation of ILRs in 15 horses with AF and 13 horses in sinus rhythm. Holter ECGs were recorded at: 1, 4, 8, 12 and 16 weeks of AF. The ILR ECGs were compared with surface ECGs to assess diagnostic sensitivity and specificity. (II) Eighty horses (43 Warmbloods, 37 Standardbreds) with ILRs were monitored for 367 days [IQR 208–621].Results(I) ILRs detected AF on all recording days, in horses with AF, with a sensitivity of 66.1% (95% CI: 65.8–66.5) and a specificity of 99.99% (95% CI: 99.97–99.99). The sensitivity remained consistent across all time points. (II) The incidence of pAF was 6.3% (5/80). In horses with pAF, the PPV ranged from 8% to 87%. Increased body condition score (BCS > 6/9) was associated with an increased number of false positive episodes (p = 0.005).Main limitations(I) Horses were stabled during the ECG recordings, and AF was induced, rather than naturally occurring pAF. (II) Integrated algorithm in this ILR is optimised for AF detection in humans using remote monitors. Additionally, sensing is affected by motion artefacts.ConclusionThe ILR reliably detected AF in resting horses, particularly in horses with normal BCS (6/9). The ILR proved useful to detect pAF and is recommended alongside Holter monitoring for diagnostic workup of horses with suspected pAF.

Funder

Danmarks Frie Forskningsfond

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3