Effect of immediate all‐digital restoration of single posterior implants: The SafetyCrown concept on patient‐reported outcome measures, accuracy, and treatment time—A randomized clinical trial

Author:

Waltenberger Lukas1ORCID,Reich Sven1,Zwahlen Marcel2ORCID,Wolfart Stefan1

Affiliation:

1. Department of Prosthodontics and Biomaterials, Centre for Implantology RWTH Aachen University Hospital Aachen Germany

2. Institute of Social and Preventive Medicine University of Bern Bern Switzerland

Abstract

AbstractObjectiveThe SafetyCrown workflow facilitates the immediate restoration of posterior single sites with the one‐abutment/one‐time concept. This randomized clinical trial aimed to assess the direct effect of immediate restoration on dental patient‐reported outcomes (dPROs), feasibility, implant accuracy, and time.Materials and MethodsParticipants with a single posterior edentulous site for late implant placement underwent optical impressions, shade selection, and cone beam computed tomography. After virtual treatment planning, they were randomized into the test group and the control group. For the test group, individual definitive hybrid abutments were prefabricated. The next step was a fully guided surgery with printed guides. After the implant was placed using guided surgery, the abutment was inserted. A chairside CAD/CAM workflow was used to provide the patient with a provisional restoration. Implants in the control group were left submerged to heal. Oral health‐related quality of life (OHRQoL) was assessed using the OHIP‐G14, and dPRO was measured using a 10‐item visual analog scale (VAS) questionnaire. Additional measurements of implant accuracy and time were performed. Follow‐up was performed 7 to 10 days after implant placement.ResultsThirty‐nine participants with 45 restorations were included (test group: 23, control: 22). Immediate restoration was successful in 21 out of 23 implants (91.3%) in the test group. Both groups exhibited decreased OHRQoL without significant intergroup differences, while patient satisfaction was high overall. Test group participants perceived higher benefits and satisfaction with immediate loading than participants in the control group. Implant accuracy averaged 0.60 mm at the shoulder and 0.95 mm at the apex. Operative time was longer in the immediate loading group (61.9 min) than in the control group (32.1 min) (p < 0.001).ConclusionsConsidering the limitations, the immediate restoration of late placed posterior implants using the described workflow proved feasible in 21 out of 23 cases. Both groups achieved high patient satisfaction with no differences in OHRQoL during the first week. Patients who received immediate loading rated the benefits very highly and were satisfied with the provisional restoration during the healing period.

Funder

International Team for Implantology

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3