Energy‐based devices and hyaluronic acid filler, polymer filler, and threads: Cadaveric study

Author:

Yi Kyu‐Ho12ORCID

Affiliation:

1. Division in Anatomy and Developmental Biology, Department of Oral Biology Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry Seoul Korea

2. Maylin Clinic (Apgujeong) Seoul Korea

Abstract

AbstractIntroductionThe objective of this experiment was to investigate the thermal effects on hyaluronic acid fillers, PCL fillers, and PDO threads when exposed to controlled heat. This study aims to provide insights into how these materials respond to thermal energy, which is crucial for safe and effective cosmetic procedures involving combined modalities.Materials and MethodsCadaveric tissue was utilized to simulate clinical conditions. Hyaluronic acid fillers were injected at approximately 1 mm and 5 mm thicknesses, with variations in G' value (high and low). PCL fillers were similarly injected in 1 mm and 5 mm thicknesses. PDO threads were also inserted. All materials were injected at a depth of 2 cm. A thermometer was used to measure heat penetration, and a multi‐wavelength laser was applied to the tissue. The temperature was maintained at 60°C for 5 min to assess whether heat penetrated more than 3 cm in thickness. Observations were made regarding the heat distribution and any physical changes in the fillers and threads.ResultsIn thick layers, heat accumulated above the PCL filler without penetrating deeper layers. In thin layers, heat penetration was observed. For the HA fillers, heat energy was not blocked, regardless of the G' value or thickness. For the threads, no significant heat blockage effect was observed. For all materials, no visual changes were detected in any of the materials due to temperature exposure.DiscussionThe findings suggest that the thickness and composition of fillers significantly influence heat penetration. Thick PCL fillers act as a thermal barrier, whereas thin PCL fillers allow deeper heat penetration. Hyaluronic acid fillers do not impede heat transfer, regardless of their physical properties. PDO threads do not exhibit any notable thermal resistance. These insights are essential for optimizing the safety and efficacy of combined filler and energy‐based device treatments in esthetic medicine.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3