Operative Effect Comparison of Flexible Drill Guiding vs. Traditional Drill Guiding Template for Lower Cervical Pedicle Screw Insertion: A Retrospective Analysis

Author:

Wu Chao12ORCID,Deng Jiayan2,Hu Haigang1,Shen Danwei2,Qin Binwei13,Wang Xiangyu1,Gao Tao1,Xu Lian1

Affiliation:

1. Department of Orthopaedics Zigong Fourth People's Hospital Zigong China

2. Institute of Digital Medicine, Zigong Academy of Big Data for Medical Science and Artificial Intelligence Zigong China

3. Department of Orthopaedics Hospital of Southwest Medical University Luzhou China

Abstract

ObjectiveAccurately inserting pedicle screws is the key point of posterior pedicle screw fixation for lower cervical spine (C3–C7) instability. 3D printing technology can improve the accuracy of screw placement. This study compared the safety of 3D‐printed flexible drill guiding template vs. traditional rigid drill guiding template for lower cervical pedicle screw insertion.MethodsThis was a retrospective study. A total of 34 patients who underwent lower cervical pedicle screw fixation from March 2018 to May 2021 were enrolled in this study, and they were divided into the flexible drill flexible drill group and the traditional drill group. A total of 18 patients in the flexible drill flexible drill group underwent pedicle screw fixation assisted by 3D printed flexible drill guiding templates for the lower cervix, and 16 patients in the traditional drill group underwent pedicle screw fixation assisted by 3D printed regular drill guiding templates for the lower cervix. The length of the incision and intraoperative blood loss during surgery were recorded and compared for the two groups. The grade, deviation of the screw entry point, deviation of the screw medial angle and screw length were measured and compared after surgery for the two groups by independent‐sample tests.ResultsThere was a significant difference in the length of the incision and blood loss between the two groups (P < 0.05). There was a significant difference between the two groups for grade (P = 0.016). The deviation of the screw entry point was 0.65 ± 0.50 mm in the flexible drill group and 0.78 ± 0.83 mm in the traditional drill group. The deviation of the screw medial angle was 2.14 ± 1.78 in the flexible drill group and 4.23 ± 2.51 in the traditional drill group, with a significant difference between the two groups (P < 0.05).ConclusionCompared with regular guiding techniques, lower cervical pedicle screw placement assisted by multistep navigation templates and flexible K‐wires results in less trauma and better safety.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3