Redefining ITT cortisol thresholds on Abbott platforms to prevent misdiagnosis of adrenal insufficiency

Author:

Lazarus Katharine12ORCID,Hayes Annabel2,Narula Kavita12,Papadopolou Debbie1,Tan Tricia M.‐M.123,Meeran Karim12ORCID,Choudhury Sirazum123ORCID

Affiliation:

1. Department of Endocrinology Imperial College Healthcare NHS Trust London UK

2. Department of Metabolism, Digestion and Reproduction, Division of Diabetes, Endocrinology and Metabolism Imperial College London London UK

3. Department of Clinical Biochemistry North West London Pathology London UK

Abstract

AbstractBackgroundAdrenal insufficiency (AI) is a life‐threatening condition which requires long term glucocorticoid replacement. The insulin tolerance test (ITT) is the current gold standard test for diagnosis of secondary AI, but the widely accepted cut‐off value of a peak cortisol of less than 500 nmol/L assumes that anyone who does not reach this value has AI and thus requires full replacement. The cut‐off used to diagnose AI is also founded on outdated assays. Use of this cut‐off in an era of more specific immunoassays therefore risks misdiagnosis, subsequent unnecessary glucocorticoid exposure and associated adverse effects with increased mortality risk.Design, Patients and MeasurementsThis retrospective analysis assessed 300 ITT cortisol responses using the Abbott Architect and Alinity analyser platforms in patients with suspected AI over a period of 12 years (August 2010 to January 2022), at a tertiary centre.ResultsPatients were classified as having AI or not, based on a comprehensive clinical review of electronic patient records from the point of test to the present day by a panel of pituitary and adrenal specialists. Using the current institutional cut‐off value of 500 nmol/L, receiver operating characteristic analysis identified a 100.0% sensitivity and 43.6% specificity (area under the curve 0.979). Using a lower cortisol threshold value of 416 nmol/L on the Abbott analyser platform maintained a sensitivity of 100.0% and improved the specificity to 86.7%.ConclusionThis data supports lowering the Abbott analyser ITT peak cortisol threshold to 416 nmol/L. Use of this improved cut‐off avoids unnecessary glucocorticoid replacement therapy in 104 (34.7%) of individuals in this study. All patients remained well with at least 1 year longitudinal follow up of glucocorticoid replacement.

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3