Performance evaluation of the Sysmex XN‐1000V in side‐by‐side comparison with the Siemens ADVIA 120 and manual methods for healthy CD Sprague–Dawley rats and CD‐1 mice

Author:

Schroeder Jill M.1ORCID,Lee Hsiu‐Yung C.2,Schultze Albert E.1ORCID

Affiliation:

1. Pathology Department, Lilly Research Laboratories Eli Lilly and Company, Lilly Corporate Center Indianapolis Indiana USA

2. Global Statistics Department, Lilly Research Laboratories Eli Lilly and Company, Lilly Corporate Center Indianapolis Indiana USA

Abstract

AbstractBackgroundThe Sysmex XN‐1000V automated hematology analyzer with multispecies software was released in June 2017 for use in research laboratories. Laser light, impedance, fluorescent staining, and fluorescent flow cytometry are used to analyze whole blood for CBC, reticulocyte counts, and WBC counts, including a 5‐part differential leukocyte analysis.ObjectivesA side‐by‐side comparison of the Sysmex XN‐1000V with the Siemens ADVIA 120 in analyzing blood from healthy mice and rats will provide insight into the performance of the new analyzer and its capabilities for use in drug development studies. Method correlation analyses on normal mouse and rat hematology data collected with both analyzers and manual reference methods will help determine the reliability of the data produced using the Sysmex XN‐1000V analyzer.MethodsWhole blood samples collected in K2EDTA from healthy CD‐1 mice and CD Sprague–Dawley rats were analyzed in parallel with the XN‐1000V and ADVIA 120 analyzers. Male and female mice, approximately 6–9 weeks old, and male and female rats, approximately 7–9 weeks old, were included in this study. Manual reference methods for WBC differential leukocyte analysis and packed cell volume (PCV) measurements were also performed. EP Evaluator version 11.2 (Data Innovations LLC, South Burlington, VT, USA) was used for method comparison statistical analysis.ResultsMost hematologic parameters for naïve mice and rats achieved correlation in the fair to excellent range, with the majority showing very good to excellent correlation with low biases (<11.0%) for cohorts analyzed separately and when cohort data were combined.ConclusionsThe Sysmex XN‐1000V Hematology Analyzer provided comparable results to those obtained from the Siemens ADVIA 120. We found the Sysmex XN‐1000V Hematology Analyzer to be acceptable for use in drug development studies for rats and mice.

Publisher

Wiley

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3