Implementation of fully closed‐loop insulin delivery for inpatients with diabetes: Real‐world outcomes

Author:

Boughton Charlotte K.12ORCID,Hartnell Sara1,Hobday Nicola1,Lake Andrea1,Davenport Katy1,Daly Aideen1,Ward Candice1,Taylor Caroline1,Hovorka Roman2ORCID,Bansiya Vishakha1

Affiliation:

1. Wolfson Diabetes and Endocrine Clinic Cambridge University Hospitals NHS Foundation Trust Cambridge UK

2. Wellcome‐MRC Institute of Metabolic Science University of Cambridge Cambridge UK

Abstract

AbstractAimsFully closed‐loop insulin delivery has been shown in clinical trials to be safe and improve glucose control compared with standard insulin therapy in the inpatient setting. We investigated the feasibility of implementing the approved CamAPS HX fully closed‐loop system in a hospital setting.MethodsThis implementation project was conducted in a large teaching hospital in Cambridge, UK. Healthcare professional training was multimodal including face‐to‐face workshops, online learning modules and supported by standard operating procedures. Set‐up and maintenance of closed‐loop devices were undertaken by the inpatient diabetes team. Selection of suitable patients was multidisciplinary and prioritised those with more challenging diabetes management. Demographic and clinical data were collected from electronic health records and diabetes data management platforms.ResultsIn the 12 months since the closed‐loop system was implemented, 32 inpatients (mean ± SD age 61 ± 16 years, 8 females, 24 males) used closed‐loop insulin delivery during their admission, across medical and surgical wards in the hospital with a total of 555 days of closed‐loop glucose control (median [IQR]: 14 [6, 22] days per inpatient).The time spent in target glucose range 3.9–10.0 mmol/L was 53.3 ± 18.3%. Mean glucose was 10.7 ± 1.9 mmol/L with 46.0 ± 18.2% of time spent with glucose >10.0 mmol/L. Time spent with sensor glucose below 3.9 mmol/L was low (median [IQR]: 0.38 [0.00, 0.85]). There were no episodes of severe hypoglycaemia or diabetic ketoacidosis during closed‐loop use.ConclusionsWe have demonstrated that the fully closed‐loop system can be safely and effectively implemented by a diabetes outreach team in complex medical and surgical inpatients with challenging glycaemic control.

Publisher

Wiley

Subject

Endocrinology,Endocrinology, Diabetes and Metabolism,Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3