Novel Claw‐shaped Bone Plate in Complex Unstable Scapular Neck and Body Fractures: Comparison with Reconstruction Locking Plate

Author:

Shi Huiming12ORCID,Zhang Kun3,Hu Yuanjun2,Wu Wei2,Liu Ning2,Lu Haixia1

Affiliation:

1. School of Basic Medical Sciences Xi'an Jiaotong University Xi'an China

2. Traumatic Orthopaedics Department Hanzhong Central Hospital Hanzhong China

3. Orthopaedics Department of Xi'an Honghui Hospital Xi'an China

Abstract

ObjectiveFor complex and unstable scapular fractures requiring simultaneous fixation of the glenoid neck, the lateral margin of the body, and/or the scapular diaphysis, reconstruction locking plate is difficult to achieve satisfactory fixation. In order to optimize the fixation effect, the newly designed claw‐shaped bone plate was designed for fixing such fractures. We also evaluate the clinical effects and follow‐up at an average of 1 year after treatment in scapular internal fixation by using reconstruction locking plate and claw‐shaped bone plate in complex unstable scapular body and glenoid neck fracture.MethodsA retrospective study was conducted from 2018 to 2021, thirty‐three patients (27 males and six females) who were defined unstable scapular fractures by Ada–Miller. Fifteen patients (52.86 ± 8.26 years) received claw‐shaped bone plate and 18 cases (51.61 ± 11.31 years) received reconstruction locking plate with the intermuscular approach. The clinical effect was evaluated based on the operation time, intraoperative blood loss, surgical complications, clinical healing time and Constant–Murley score (CMS). The data analysis by Student t, Mann–Whitney U test and Pearson's chi squared test.ResultsCompared with reconstruction locking plate, the claw‐shaped bone plate showed shorter operation time (102.73 ± 18.43 min vs. 156 ± 37.53, P < 0.0001), higher CMS (94.00 ± 4.07 vs. 89.88 ± 5.42, P = 0.02) and no differences between the two groups regarding intraoperative blood loss (208.00 ± 96.45 mL vs. 269.44 ± 120.21, P = 0.12) and clinical healing times (9.96 ± 1.52 vs. 10.05 ± 1.67, P = 0.87). Follow‐up were conducted at first, third, 6 and 12 months after surgery. The operation was successful in all patients with no intraoperative complications.ConclusionsFor the treatment of complex and unstable scapular neck body fractures, the application of claw‐shaped bone plate demonstrated short operation time, better stability of the fracture block, and higher CMS. In the intraoperative and postoperative follow‐up showed better clinical results and rehabilitation effects.

Publisher

Wiley

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Shoulder and Elbow Surgery Special Issue;Orthopaedic Surgery;2023-08

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3