Comparison of conjunctival pedicle flap to corneal fixation strength achieved by Tisseel® fibrin glue, ethyl cyanoacrylate adhesive, ReSure® hydrogel sealant, and conventional suturing with 8‐0 VICRYL® ophthalmic suture

Author:

VerHulst Elodie M.1ORCID,Galarza Roxanne M. Rodriguez1ORCID,Herring Ian P.1,Ramos Renata Velloso1,Kemper Andrew R.2

Affiliation:

1. Department of Small Animal Clinical Sciences Virginia Maryland College of Veterinary Medicine, Virginia Tech Blacksburg Virginia USA

2. Department of Biomedical Engineering and Mechanics College of Engineering, Virginia Tech Blacksburg Virginia USA

Abstract

AbstractObjectiveTo determine and compare the fixation strength of conjunctival pedicle flaps to cornea achieved via conventional ophthalmic suture and three different adhesive compounds.Animals StudiedEx vivo porcine globes.ProceduresFollowing a 6 mm wide 500‐micron‐restricted depth lamellar keratectomy, conjunctival pedicle flaps were secured to the keratectomy site with either 8‐0 VICRYL® suture or one of three adhesive products, including Tisseel® bioadhesive, ReSure® synthetic adhesive, or ethyl cyanoacrylate adhesive (n = 10 per surgical group). Adhesive application protocol varied by product based upon adhesive biocompatibility. Corneoconjunctival tissues were then harvested, clamped in a tensile testing device, and loaded at a rate of 1 mm/s under video surveillance until the point of failure. Peak load was determined for each test and used to compare fixation strength between samples.ResultsForty conjunctival flaps were performed, with 6 omitted from evaluation due to dehiscence prior to tensile testing. Of the 34 flaps analyzed, 10 were secured with suture, 10 with cyanoacrylate, 8 with ReSure®, and 6 with Tisseel®. Flaps secured with suture withstood significantly higher applied tensile force compared with cyanoacrylate (p = .02474), ReSure® (p = .00000), and Tisseel® (p = .00002). Flaps secured with cyanoacrylate withstood significantly greater force than those secured with ReSure® and Tisseel® (p = .01194 and 0.01798, respectively). There was no significant difference in fixation strength between ReSure® and Tisseel® glue (p = .95675).ConclusionsConjunctival pedicle flap fixation using 8‐0 VICRYL® suture fixation was able to withstand significantly greater maximum tensile force compared to ReSure®, Tisseel®, or cyanoacrylate adhesives. Fixation strength achieved with cyanoacrylate adhesive was significantly greater than that achieved with ReSure® or Tisseel®.

Publisher

Wiley

Reference75 articles.

1. Corneal ulcerative disease in dogs under primary veterinary care in England: epidemiology and clinical management;O'Neill DG;Canine Genet Epidemiol,2017

2. Conjunctival pedicle grafting in the treatment of corneal ulcers in the dog and cat;Hakanson N;J Am Anim Hosp Assoc,1987

3. Further comments on conjuctival pedicle grafting in the treatment of corneal ulcers in the dog and cat;Hakanson N;J Am Anim Hosp Assoc,1988

4. Outcome of conjunctival flap repair for corneal defects with and without an acellular submucosa implant in 73 canine eyes;Dorbandt DM;Vet Ophthalmol,2015

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3