Reliability of the Enterprise Point‐of‐Care (EPOC) blood analyzer's calculated arterial oxygen‐hemoglobin saturation in immobilized white rhinoceroses (Ceratotherium simum)

Author:

Mtetwa Thembeka K.123ORCID,Snelling Edward P.23,Donaldson Ashleigh C.12,Buss Peter E.245,Meyer Leith C. R.12

Affiliation:

1. Department of Paraclinical Sciences, Faculty of Veterinary Science University of Pretoria Onderstepoort South Africa

2. Centre for Veterinary Wildlife Research, Faculty of Veterinary Science University of Pretoria Onderstepoort South Africa

3. Department of Anatomy and Physiology, Faculty of Veterinary Science University of Pretoria Onderstepoort South Africa

4. Veterinary Wildlife Services, South African National Parks, Kruger National Park Skukuza South Africa

5. Department of Production Animal Studies, Faculty of Veterinary Science University of Pretoria Onderstepoort South Africa

Abstract

AbstractBackgroundEnterprise Point‐of‐Care (EPOC) blood analysis is used routinely in wildlife veterinary practice to monitor blood oxygenation, but the reliability of the EPOC calculated arterial oxygen‐hemoglobin saturation (cSaO2) has never been validated in the white rhinoceros (Ceratotherium simum), despite their susceptibility to hypoxemia during chemical immobilization.ObjectivesWe aimed to evaluate the reliability of the EPOC cSaO2 by comparing it against arterial oxygen‐hemoglobin saturation (SaO2) measured by a co‐oximeter reference method in immobilized white rhinoceroses.MethodsMale white rhinoceroses in two studies (both n = 8) were immobilized by darting with different etorphine‐based drug combinations, followed by butorphanol or saline (administered intravenously). Animals in both studies received oxygen via intranasal insufflation after 60 min. Blood samples were drawn, at predetermined time points, from a catheter inserted into the auricular artery and analyzed using the EPOC and a co‐oximeter. Bland–Altman (to estimate bias and precision) and area root mean squares (ARMS) plots were used to determine the reliability of the EPOC cSaO2 compared with simultaneous co‐oximeter SaO2 readings.ResultsThe rhinoceros were acidotic (pH of 7.3 ± 0.1 [mean ± standard deviation]), hypercapnic (PaCO2 of 73.7 ± 10.5 mmHg), and normothermic (body temperature of 37.4 ± 1.8°C). In total, 389 paired cSaO2‐SaO2 measurements were recorded (the cSaO2 ranged between 13.2% and 99.0%, and the SaO2 ranged between 11.8% and 99.9%). The EPOC cSaO2 readings were unreliable (inaccurate, imprecise, and poor ARMS) across the entire saturation range (bias −6%, precision 5%, and ARMS 8%).ConclusionsThe EPOC cSaO2 is unreliable and should not be used to monitor blood oxygenation in immobilized white rhinoceroses.

Publisher

Wiley

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3