Clinical utility of point‐of‐care glucose testing in the assessment of gestational diabetes: Prospective cohort study

Author:

Al‐Hasani Wiaam1,Ranasinghe Ruvini1,Rogers Helen2,Spanier William1,Spears Katie2,Gayle Carol2,Long Lisa3,Dimitriadis Georgios K.45,Hunt Katharine F.25,Vincent Royce P.15ORCID

Affiliation:

1. Department of Clinical Biochemistry (Synnovis) King's College Hospital NHS Foundation Trust London UK

2. Department of Diabetes King's College Hospital NHS Foundation Trust London UK

3. Department of Obstetrics King's College Hospital NHS Foundation Trust London UK

4. Department of Endocrinology King's College Hospital NHS Foundation Trust London UK

5. School of Life Course Sciences, Faculty of Life Sciences and Medicine King's College London London UK

Abstract

AbstractObjectiveTo assess the clinical utility of point‐of‐care (POC) capillary blood glucose (CBG) testing in the assessment of gestational diabetes mellitus (GDM) during oral glucose tolerance test (OGTT).DesignProspective cohort study.SettingAntenatal clinics at King's College Hospital.PopulationWomen screened for GDM between March and June 2020.MethodsThe CBG was measured using the POC StatStrip® test and the venous plasma glucose (VPG) was measured by Roche analyser (Cobas 8000 c702). GDM was diagnosed based on the 2015 National Institute for Health and Clinical Excellence (NICE) Clinical Guideline criteria. The two methods were compared statistically using Analyse‐It 5.40.2.Main outcome measuresDiagnostic sensitivity, specificity, positive and negative predictive values (PPV and NPV) for the POC StatStrip® test, compared with VPG measured by reference laboratory method.ResultsA total of 230 women were included. The number and percentage of women with glucose concentrations above the GDM threshold using the POC StatStrip® test versus laboratory VPG measurement was 15 (6.5%) versus eight (3.4%) at fasting and 105 (45.6%) versus 72 (31.1%) at 2 h, respectively. The sensitivity and specificity values (and 95% CIs) for the POC StatStrip® test were 88% (52%–99%) and 97% (93%–98%) at fasting and 97% (91%–99%) and 79% (71%–84%) at 2 h, respectively. However, the specificity and the NPV for the POC StatStrip® test for concentrations of ≤5.0 mmol/L at fasting or <7.5 mmol/L at 2 h were 100%, and the sensitivity and the PPV for concentrations of >9.5 mmol/L at 2 h were 100%.ConclusionsIn our cohort the POC measurement of CBG cannot entirely replace the laboratory method for the OGTT; however, it can be used to rule out/rule in GDM for glucose concentrations of ≤5.0 mmol/L at fasting or <7.5/>9.5 mmol/L at 2 h.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3