Improving sensitivity through data augmentation with synthetic lymph node metastases for AI‐based analysis of PSMA PET‐CT images

Author:

Trägårdh Elin12ORCID,Ulén Johannes3,Enqvist Olof34,Edenbrandt Lars5ORCID,Larsson Måns3

Affiliation:

1. Department of Translational Medicine and Wallenberg Centre for Molecular Medicine Lund University Malmö Sweden

2. Department of Clinical Physiology and Nuclear Medicine Skåne University Hospital Malmö Sweden

3. Eigenvision AB Malmö Sweden

4. Department of Electrical Engineering Chalmers University of Technology Gothenburg Sweden

5. Department of Molecular and Clinical Medicine, Institute of Medicine, Sahlgrenska Academy University of Gothenburg Gothenburg Sweden

Abstract

AbstractBackgroundWe developed a fully automated artificial intelligence (AI)AI‐based‐based method for detecting suspected lymph node metastases in prostate‐specific membrane antigen (PSMA)(PSMA) positron emission tomography‐computed tomography (PET‐CT)(PET‐CT) images of prostate cancer patients by using data augmentation that adds synthetic lymph node metastases to the images to expand the training set.MethodsSynthetic data were derived from original training images to which new synthetic lymph node metastases were added. Thus, the original training set from a previous study (n = 420) was expanded by one synthetic image for every original image (n = 840), which was used to train an AI model. The performance of the AI model was compared to that of nuclear medicine physicians and a previously developed AI model. The human readers were alternately used as a reference and compared to either another reading or AI model.ResultsThe new AI model had an average sensitivity of 84% for detecting lymph node metastases compared with 78% for human readings. Our previously developed AI method without synthetic data had an average sensitivity of 79%. The number of false positive lesions were slightly higher for the new AI model (average 3.3 instances per patient) compared to human readings and the previous AI model (average 2.8 instances per patient), while the number of false negative lesions was lower.ConclusionsCreating synthetic lymph node metastases, as a form of data augmentation, on [18F]PSMA‐1007F]PSMA‐1007 PETPET‐CT‐CT images improved the sensitivity of an AI model for detecting suspected lymph node metastases. However, the number of false positive lesions increased somewhat.

Funder

Knut och Alice Wallenbergs Stiftelse

Swedish Cancer Foundation

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3